Simultaneous stimulation of 2 left ventricular (LV) sites could enhance the effectiveness of cardiac resynchronization therapy (CRT). The aim of this study was to evaluate the acute hemodynamic response to dual-site LV CRT. Two LV pacing leads were successfully implanted in 12 CRT candidates (New York Heart Association classes III to IV, QRS >or=120 ms). Target positions were the lateral or posterolateral vein (site A) and anterior or anterolateral vein (site B). A conductance catheter was placed in the left ventricle for pressure-volume measurements. Tested CRT configurations were alternated by atrial overdrive pacing at a fixed rate and included site A and B single-site CRT and dual-site LV CRT (2 LV sites plus right ventricular apex) at 4 atrioventricular intervals. Overall, single-site LV CRT significantly enhanced stroke volume, stroke work, maximum pressure derivative, and conductance-derived indexes of LV synchrony when delivered in site A, whereas no significant changes were noticed with pacing in site B. Specifically, site-A pacing resulted in a higher stroke volume increase (LV pacing site associated with the best hemodynamic response [best-LV]) in 8 patients, and site-B pacing, in 4 patients. At intermediate atrioventricular intervals, dual-site LV CRT resulted in improved stroke volume, stroke work, maximum pressure derivative, and LV synchrony with respect to single-site CRT when delivered at the best-LV (all p <0.05). However, single-site CRT at best-LV produced results similar to dual-site LV CRT when the atrioventricular interval was optimized in each patient. In conclusion, adding a second LV lead does not result in further improvement in acute hemodynamic response with respect to standard CRT when the single LV pacing site and atrioventricular interval are optimal.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2008.08.016DOI Listing

Publication Analysis

Top Keywords

dual-site crt
12
single-site crt
12
stroke volume
12
crt
9
left ventricular
8
cardiac resynchronization
8
resynchronization therapy
8
hemodynamic response
8
vein site
8
atrioventricular intervals
8

Similar Publications

Cardiac resynchronization therapy (CRT) can substantially improve dyssynchronous heart failure and reduce mortality. However, about one-third of patients who are implanted, derive no measurable benefit from CRT. Non-response may partly be due to suboptimal activation of the left ventricle (LV) caused by electrophysiological heterogeneities.

View Article and Find Full Text PDF

Objectives: This study sought to determine the long-term effect of dual-site ventricular pacing (i.e., cardiac resynchronization therapy [CRT]) versus single-site pacing in patients with Fontan physiology and high-grade atrioventricular block (AVB).

View Article and Find Full Text PDF

Background: Controversy remains regarding the use of cardiac resynchronization therapy (CRT) in patients with heart failure with right bundle branch block (RBBB) and reduced left ventricular (LV) ejection fraction. Moreover, little is known about acute hemodynamic changes with CRT in this subgroup as compared with patients with left bundle branch block (LBBB).

Objective: The purpose of this study was to evaluate the acute biventricular hemodynamic response of CRT and other pacing configurations, including the effects of atrioventricular (AV) delay and atrial pacing, to understand the effects of CRT in RBBB.

View Article and Find Full Text PDF

Background: In patients with triple valve replacement developing third-degree atrioventricular block (AVB), the most appropriate approach for permanent pacemaker implantation remains questionable.

Case Presentation: In this case presentation, we first described the approach of implantation of the cardiac resynchronization therapy pacemaker (CRT-P) via one bipolar pacing lead in middle cardiac vein (MCV) and one quadripolar pacing lead in anterior interventricular vein (AIV) in a patient developing complete AVB, who had been previously diagnosed with rheumatic valvular heart disease with triple valve replaced. After the CRT-P implantation, the two pacing leads in coronary sinus (CS) provided a dual-site ventricular pacing from the anterior septum and posterior septum, which resulted in a narrow QRS complex and an increased ventricular synchrony.

View Article and Find Full Text PDF
Article Synopsis
  • Dual-site right ventricular pacing (Dual RV) was studied as an alternative for heart failure patients where the coronary sinus lead could not be implanted during cardiac resynchronization therapy (CRT).
  • A 12-year retrospective assessment showed that patients using Dual RV had a higher rate of all-cause mortality or heart transplant compared to matched controls, indicating poorer long-term outcomes.
  • The use of Dual RV also led to significantly more cardiac device-related infections, suggesting it is less favorable than traditional CRT methods.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!