This second paper of the series considers the spread of the "effective stimulation field" (ESF) produced by monopolar biphasic stimulation of an electrode within scala tympani, in subjects implanted with the Nucleus 24 cochlear implant system (three with straight and two with Contour electrode arrays). A novel measure of the ECAP was employed, using the Neural Response Telemetry (NRT) system. The ESF provides a patient-specific measure of the "ability" of the stimulation field to excite neurons at differing locations around the cochlea. The results were interpreted with the aid of simple finite element computational models of the electric field. The finite element models were used to generate template field spread functions that differed with radial distance of the stimulated electrode from the modiolus. Relative to a template field function for the appropriate radial distance, the ESF spread on average approximately twice as broadly (a scaling factor of two). The magnitude of this scaling factor was considered to be indicative of the site of excitation on the neural fibers. The relationship between two ECAP measures, the spread of ESF and the "spread of excitation" (SOE), is discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.heares.2008.11.004DOI Listing

Publication Analysis

Top Keywords

cochlear implant
8
stimulation field
8
finite element
8
template field
8
radial distance
8
scaling factor
8
spread
5
field
5
esf
5
practical model
4

Similar Publications

Purpose: Cochlear implants (CI) are the most successful bioprosthesis in medicine probably due to the tonotopic anatomy of the auditory pathway and of course the brain plasticity. Correct placement of the CI arrays, respecting the inner ear anatomy are therefore important. The ideal trajectory to insert a cochlear implant array is defined by an entrance through the round window membrane and continues as long as possible parallel to the basal turn of the cochlea.

View Article and Find Full Text PDF

Robot-assisted vs. manual cochlear implant electrode array insertion in four children.

Eur Arch Otorhinolaryngol

January 2025

Department of Audiovestibology, ASST dei Sette Laghi, Via Lazio, 21100, Varese, VA, Italy.

Purpose: Evaluate the feasibility and safety of a robotic electrode insertion in pediatric cochlear implantation and compare the results with manually inserted electrodes in the same subject.

Methods: Retrospective case series review of four children who underwent bilateral cochlear implantation with the same array: on one side, the array was inserted using the robot, while on the other side the array was inserted manually. Behavioural and electrophysiological measures were compared.

View Article and Find Full Text PDF

Speech Perception in Noise After Cochlear Implantation for Single-Sided Deafness: A Randomized Clinical Trial.

JAMA Otolaryngol Head Neck Surg

January 2025

Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, the Netherlands.

Importance: There is a lack of high level of evidence studies comparing the effect of different treatment options for single-sided deafness (SSD).

Objective: To determine the effect of a cochlear implant (CI), bone conduction device (BCD), contralateral routing of signals hearing aid (CROS), and no treatment on speech perception in noise outcomes in patients with SSD.

Design, Setting, And Participants: In this single-center randomized clinical trial, adult patients with SSD were randomized into 3 groups: CI; a trial period with first a BCD on a headband and then a CROS; or a trial period with first a CROS and then a BCD on a headband.

View Article and Find Full Text PDF

When listening to speech under adverse conditions, listeners compensate using neurocognitive resources. A clinically relevant form of adverse listening is listening through a cochlear implant (CI), which provides a spectrally degraded signal. CI listening is often simulated through noise-vocoding.

View Article and Find Full Text PDF

Background: Pediatric cochlear implant (CI) recipients with cochlear malformations face challenges due to variable speech recognition outcomes.

Aims/objectives: This study assesses the predictive value of intraoperative electrically evoked compound action potential (eCAP) thresholds, residual hearing, age at implantation, Intelligent Quotient (IQ), and malformation type for speech recognition outcomes.

Material And Methods: A prospective cohort of 52 children (aged 1-4 years) with cochlear malformations who underwent CI between 2016 and 2024 was analyzed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!