Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: The aim of this study was to evaluate the influence of different weighting factors on contrast enhancement, signal-to-noise ratio (SNR), and image quality in image fusion in dual energy computed tomography (DECT) angiography.
Material And Methods: Fifteen patients underwent a CT angiography of the aorta with a SOMATOM Definition Dual Source CT (DSCT; Siemens, Forchheim, Germany) in dual energy mode (DECT) (tube voltage: 80 and 140 kVp; tube current: 297 eff. mA and 70 eff. mA; collimation, 14 x 1.2 mm). Raw data were reconstructed using a soft convolution kernel (D30f). Fused images were calculated using a spectrum of weighting factors (0.0, 0.1, 0.3, 0.5, 0.7, 0.9, and 1.0) generating different ratios between the 80- and 140-kVp images (eg, factor 0.5 corresponds to 50% image information from the 140- and the 80-kVp image). Both CT values and SNR were measured in the descending aorta (levels of celiac trunk, renal arteries, and aortic bifurcation), in the right and left common iliac artery and in paraaortal fat. Image quality was evaluated using a 5-point grading scale. Results were compared using paired t-tests and nonparametric paired Wilcoxon tests.
Results: Statistically significant increases in mean CT values were seen in vessels when increasing weighting factors were used (all P
Conclusion: Different weighting factors used to create fused images in DECT cause statistically significant differences in CT value, SNR, and image quality. Best results were obtained using the weighting factor 0.5, which we recommend for image fusion in DECT angiography.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/RLI.0b013e31818c3d4b | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!