Machine perfusion for cardiac allograft preservation.

Curr Opin Organ Transplant

Department of Cardiovascular and Thoracic Surgery, University of Texas Southwestern Medical Center at Dallas, Dallas, Texas 75390-8879, USA.

Published: October 2008

Purpose Of Review: The current cardiac preservation strategy for cardiac transplantation involves arresting hearts with a crystalloid preservation solution and storing them in this solution in an ice chest. This technique has allowed good results in heart transplantation, but has limited the transport interval, and has not encouraged major efforts to expand the donor pool. Machine perfusion of explanted organs, a technique used clinically in kidney transplantation, is now under active investigation in the cardiac arena. This review examines the current status of this technology.

Recent Findings: Recent experimental studies in animals have tested machine perfusion for cardiac preservation. This technique appears to reduce the allograft ischemic burden, may permit longer preservation times, and improves early ventricular function upon reperfusion of the donor heart. The metabolic profile of the stored heart appears better preserved with machine perfusion; however, investigators have noted a risk of edema development in perfused cardiac grafts.

Summary: Early experimental results are encouraging and suggest that machine perfusion may offer superior cardiac performance after transplantation. In the future, this technology may lead to an expansion of the donor pool through greater use of expanded-criteria donors, resuscitation of ischemically injured hearts, or procurement of hearts that are donated after cardiac death.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MOT.0b013e32830fdf9aDOI Listing

Publication Analysis

Top Keywords

machine perfusion
20
cardiac
8
perfusion cardiac
8
cardiac preservation
8
donor pool
8
machine
5
preservation
5
cardiac allograft
4
allograft preservation
4
preservation purpose
4

Similar Publications

Background: Normothermic machine perfusion (NMP) provides a platform for kidney quality assessment. Donation after circulatory death (DCD) donor kidneys are associated with great ischemic injury and high intrarenal resistance (IRR). This experimental study aims to investigate the impact of different perfusion pressures on marginal kidney function and injury during NMP.

View Article and Find Full Text PDF

Designer Organs: Ethical Genetic Modifications in the Era of Machine Perfusion.

Annu Rev Biomed Eng

January 2025

1Center for Engineering for Medicine and Surgery, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA;

Gene therapy is a rapidly developing field, finally yielding clinical benefits. Genetic engineering of organs for transplantation may soon be an option, thanks to convergence with another breakthrough technology, ex vivo machine perfusion (EVMP). EVMP allows access to the functioning organ for genetic manipulation prior to transplant.

View Article and Find Full Text PDF

Background: Machine perfusion (MP), including hypothermic oxygenated machine perfusion (HOPE), dual HOPE, normothermic machine perfusion (NMP), NMP ischemia-free liver transplantation (NMP-ILT), and controlled oxygenated rewarming (COR), is increasingly being investigated to improve liver graft quality from extended criteria donors and donors after circulatory death and expand the donor pool. This network meta-analysis investigates the comparative efficacy and safety of various liver MP strategies versus traditional static cold storage (SCS).

Methods: We searched PubMed, Scopus, Web of Science, and Cochrane Controlled Register of Trials for randomized controlled trials (RCTs) comparing liver transplantation (LT) outcomes between SCS and MP techniques.

View Article and Find Full Text PDF

Introduction: Graft optimization is a necessity in order to develop uterus transplantation from brain-dead donors, as a complement to living donors, as these grafts are rare and the last organs retrieved in multiple organ donation. The aim of this study was to assess the feasibility and interest of hypothermic machine perfusion (HMP) in uterus transplantation using a porcine model; secondary outcomes were the evaluation of the graft's tolerance to a prolonged cold ischaemia time and to find new biomarkers of uterus viability.

Material And Methods: Fifteen uterus allotransplantations were performed in a porcine model, after 18 h of cold ischaemia, divided in three groups: Static cold storage in a HTK solution, HMP (with the VitaSmart (™) machine Bridge to Life Ltd.

View Article and Find Full Text PDF

Background: Membrane oxygenators facilitate extracorporeal gas exchange, necessitating the monitoring of blood gas. Recent advances in normothermic machine perfusion (NMP) for ex vivo liver offer solutions to the shortage of donor liver. However, maintaining physiological blood gas levels during prolonged NMP is complex and costly.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!