A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

High performance liquid chromatographic determination of plasma free and total tazobactam and piperacillin. | LitMetric

AI Article Synopsis

  • A high-pressure liquid chromatography (HPLC) method was developed for measuring plasma levels of tazobactam and piperacillin, requiring only 11 minutes for both sample preparation and analysis.
  • The procedure involves using acetonitrile for total drug determination and a centrifugal filter to remove proteins for free drug measurement, with high recovery rates and strong repeatability for test results.
  • This method reliably detects low concentrations of both drugs in human plasma, making it useful for monitoring patients on tazobactam therapy.

Article Abstract

A high-pressure liquid chromatography (HPLC) method with ultraviolet detection was developed for the measurement of plasma free and total tazobactam and piperacillin. This method is simple and fast, requiring only 11 min for the HPLC run and a sample preparation of about 11 min for total drugs and 10 min for free drugs. The procedure for the assay involves the treatment of plasma with acetonitrile for total drugs determination, and the use of a centrifugal filter device to deproteinize plasma for free drugs determination. The HPLC column, a Hypersil-ODS, was equilibrated with an eluent mixture composed of acetonitrile-potassium phosphate (pH 2.6). CVs for repeatability of tazobactam and piperacillin measurements ranged from 4.30 to 6.60; CVs for reproducibility ranged from 5.60 to 9.40. Mean analytical recoveries ranged from 100.4 to 103%. A linear relationship was obtained between peak area and drugs concentration in the range studied (0-62.5mg/L for tazobactam and 0-500mg/L for piperacillin). The equation for regression line were y=19x-1.4 for tazobactam and y=1.7x-0.9 for piperacillin; correlation coefficients were >0.999. The lower limit of quantitation (LLQ) for standard samples was about 0.12 mg/L for tazobactam and 0.49 mg/L for piperacillin, respectively. The lower limit of detection (LLD) was 0.06 mg/L for tazobactam and 0.24 mg/L for piperacillin. This HPLC assay for tazobactam and piperacillin is sensitive and accurate, and provides a reliable determination of both free and total tazobactam and piperacillin in human plasma, thus allowing the determination of these analytes in patients receiving tazocillin therapy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2008.11.010DOI Listing

Publication Analysis

Top Keywords

tazobactam piperacillin
20
plasma free
12
free total
12
total tazobactam
12
tazobactam
9
piperacillin
9
total drugs
8
free drugs
8
drugs determination
8
lower limit
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!