An observational time-motion study investigated logistic, programmatic and safety-related advantages and limits in the delivery of a fully liquid DTP-HepB-Hib combination vaccine versus a lyophilized combination vaccine requiring reconstitution. The study was conducted in 2006, observing 312 child vaccinations in a tertiary hospital setting in Kolkata, India. The time for vaccination was on average 46s (35.12%) lower with the fully liquid vaccine (p<0.05). In addition, the fully liquid combination was easier and potentially safer to handle and as well tolerated as the lyophilized formulation. Fully liquid combination vaccines have the potential to simplify immunization schedules, contribute to better resource management and improve efficiency of immunization programs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.vaccine.2008.11.045DOI Listing

Publication Analysis

Top Keywords

fully liquid
12
combination vaccine
12
liquid dtp-hepb-hib
8
dtp-hepb-hib combination
8
time-motion study
8
simplifying paediatric
4
paediatric immunization
4
immunization fully
4
vaccine
4
vaccine evidence
4

Similar Publications

Rapid and accurate molecular diagnostics are crucial for preventing the global spread of emerging infectious diseases. However, the current gold standard for nucleic acid detection, reverse transcription polymerase chain reaction (RT-PCR), relies heavily on traditional magnetic beads or silica membranes for nucleic acid extraction, resulting in several limitations, including time-consuming processes, the need for trained personnel, and complex equipment. Therefore, there is an urgent need for fully integrated nucleic acid detection technologies that are simple to operate, rapid, and highly sensitive to meet unmet clinical needs.

View Article and Find Full Text PDF

Research into flexible solid-state supercapacitors for wearable electronics focuses on achieving high performance and safety. Gel polymer electrolytes (GPEs) are preferred over fully solid-state electrolytes due to their better ionic conductivity while addressing safety concerns associated with liquid electrolytes. This study aims to enhance high-performance gel polymer electrolytes (HP-GPEs) by improving the ion transfer rate of polyvinyl alcohol (PVA) with sulfonated hexagonal boron nitride (known as white-graphene) and exploring how rheology influences ion-conduction within HP-GPEs.

View Article and Find Full Text PDF

High-intensity focused ultrasound (HIFU) is a noninvasive soft tissue ablation technique, which utilizes ultrasound energy to induce thermal coagulation necrosis in targeted tissues. Whether this high energy causes side effects in vivo, such as the formation of peptide bonds, has not been fully investigated. Glycylglycine is the simplest dipeptide and hence is often used as a model compound for peptide studies.

View Article and Find Full Text PDF

Introduction: Non-surgical alternatives to rhinoplasty are gaining interest but, despite its popularity, research on the long-term psychological impact and post-rhinofiller patients' satisfaction is limited. This study evaluates patient-reported satisfaction and quality of life immediately after and 6 months post-non-surgical rhinoplasty using the FACE-Q questionnaire.

Patients And Methods: This prospective study was conducted from May 2023 to March 2024, involving 83 patients who underwent rhinofiller treatments for esthetic purposes.

View Article and Find Full Text PDF

diaTracer enables spectrum-centric analysis of diaPASEF proteomics data.

Nat Commun

January 2025

Gilbert S. Omenn Department of Computational Medicine and Bioinformatics, University of Michigan, Ann Arbor, MI, USA.

Data-independent acquisition has become a widely used strategy for peptide and protein quantification in liquid chromatography-tandem mass spectrometry-based proteomics studies. The integration of ion mobility separation into data-independent acquisition analysis, such as the diaPASEF technology available on Bruker's timsTOF platform, further improves the quantification accuracy and protein depth achievable using data-independent acquisition. We introduce diaTracer, a spectrum-centric computational tool optimized for diaPASEF data.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!