A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Multi-elements (aluminium, copper, magnesium, manganese, selenium and zinc) determination in serum by dynamic reaction cell-inductively coupled plasma-mass spectrometry. | LitMetric

Background: Trace element determination in laboratory medicine is widely carried out by atomic absorption or emission spectroscopy. In the last decade, there has been a rapid growth in the use of inductively coupled plasma-mass spectrometry because of its strong detection power, and the possibility of multi-elements analysis in a single run.

Methods: Having the advantages of smaller sample volume and better detection limit, we developed a method for the simultaneous determinations of six trace elements by using 100 microL serum, and the assay can be accomplished within 3 min.

Results: The method developed gave recovery of the six elements ranging from 97% to 117%. The method covered a wide dynamic range with manganese in the range of nmol/L, while magnesium was in the range of mmol/L. The detection limits were 0.001 mmol/L, 0.05 micromol/L, 2.0 nmol/L, 0.2 micromol/L, 0.05 micromol/L, and 0.01 micromol/L for magnesium, aluminium, manganese, copper, zinc, and selenium, respectively. All the six elements had intra-assay imprecision of less than 5%, and inter-assay imprecision of less than 8%.

Conclusions: This fast and robust method is suitable for use in the clinical laboratory where short turnaround time is needed for managing patients with trace element deficiency or toxicity.

Download full-text PDF

Source
http://dx.doi.org/10.1515/CCLM.2009.006DOI Listing

Publication Analysis

Top Keywords

coupled plasma-mass
8
plasma-mass spectrometry
8
trace element
8
005 micromol/l
8
multi-elements aluminium
4
aluminium copper
4
copper magnesium
4
magnesium manganese
4
manganese selenium
4
selenium zinc
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!