Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Offal includes viscera and internal organs that have been removed from butchered animals, that may be either directly eaten or processed for the production of other foodstuff. Such organs are able to accumulate high concentrations of potentially toxic heavy metals posing a risk for human health when ingested. Because high levels of Cd and Pb may produce damages to humans, Commission Regulation no. 1881/2006 and its amendment established maximum levels for those two elements in edible bovine, porcine, and ovine offal. In the present study, a method based on microwave acid-assisted digestion and quadrupole inductively coupled plasma mass spectrometric quantification of Cd and Pb in offal was validated according to the EU common standards. The main parameters evaluated in the validation process were: the detection and the quantification limits (LoD, LoQ), the recovery, the repeatability, the within-laboratory reproducibility, the linearity range, and the standard measurement uncertainty. The results obtained for LoD and LoQ in microg kg(-1) were, respectively, Cd, 1.8 and 5.4; Pb, 5.1 and 15.5; meanwhile, the mean recovery was about 98% for Cd and 103% for Pb. Repeatability was around 5% for Cd and 4% for Pb. The expanded standard measurement uncertainty, expressed as percentage and with a coverage factor of 2, was estimated as follows: Cd, 4.9%; Pb, 8.7%. For both elements, the main contribution was due to the within-laboratory reproducibility of the measurements.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/jf8028623 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!