The purpose of this work was to investigate the differences in dose settings among the X-ray units involved in a national survey of patient doses in interventional radiology (IR). The survey was promoted by the National Society of IR and involved 10 centers. As part of the agreed quality control for the survey, entrance doses were measured in a 20-cm-thick acrylic phantom simulating a medium-sized patient. A standard digital subtraction angiography (DSA) imaging protocol for the abdomen was used at the different centers. The center of the phantom was placed at the isocenter of the C-arm system during the measurements to simulate clinical conditions. Units with image intensifiers and flat detectors were involved in the survey. Entrance doses for low, medium, and high fluoroscopy modes and DSA acquisitions were measured for a field of view of 20 cm (or closest). A widespread range of entrance dose values was obtained: 4.5-18.6, 9.2-28.4, and 15.4-51.5 mGy/min in low, medium, and high fluoroscopy mode, respectively, and 0.7-5.0 mGy/DSA image. The ratios between the maximum and the minimum values measured (3-4 for fluoroscopy and 7 for DSA) suggest an important margin for optimization. The calibration factor for the dose-area product meter was also included in the survey and resulted in a mean value of 0.73, with a standard deviation of 0.07. It seems clear that the dose setting for the X-ray systems used in IR requires better criteria and approaches.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00270-008-9470-xDOI Listing

Publication Analysis

Top Keywords

dose settings
8
settings x-ray
8
x-ray systems
8
interventional radiology
8
national survey
8
survey entrance
8
entrance doses
8
low medium
8
medium high
8
high fluoroscopy
8

Similar Publications

Importance: Hypertension is the primary cardiovascular risk factor in Africa. Recently revised World Health Organization guidelines recommend starting antihypertensive dual therapy; clinical efficacy and tolerability of low-dose triple combination remain unclear.

Objectives: To compare the effect of 3 treatment strategies on blood pressure control among persons with untreated hypertension in Africa.

View Article and Find Full Text PDF

Background: Dialysis vintage is largely dependent on the effectiveness of the delivered dose coupled with the extent of patient compliance with the prescribed treatment regimen. This study assessed the determinants and correlates of dialysis vintage. : This was a 4-year prospective, observational study.

View Article and Find Full Text PDF

Background: Female healthcare workers have unique occupational stressors and lifestyle factors that may increase their risk of metabolic disorders. This study aimed to investigate the utility of the fatty liver index (FLI) as a predictor of metabolic syndrome among female employees in the healthcare sector.

Methods: This cross-sectional study included 450 female healthcare workers aged ≥18 years, employed in various roles at a tertiary healthcare facility in Gujarat.

View Article and Find Full Text PDF

Background: K-edge subtraction (KES) imaging is a dual-energy imaging technique that enhances contrast by subtracting images taken with x-rays that are above and below the K-edge energy of a specified contrast agent. The resulting reconstruction spatially identifies where the contrast agent accumulates, even when obscured by complex and heterogeneous distributions of human tissue. This method is most successful when x-ray sources are quasimonoenergetic and tunable, conditions that have traditionally only been met at synchrotrons.

View Article and Find Full Text PDF

The impact of three-dimensional (3D) dose delivery accuracy of C-arm linacs on the planning target volume (PTV) margin was evaluated for non-coplanar intracranial stereotactic radiosurgery (SRS). A multi-institutional 3D starshot test using beams from seven directions was conducted at 22 clinics using Varian and Elekta linacs with X-ray CT-based polymer gel dosimeters. Variability in dose delivery accuracy was observed, with the distance between the imaging isocenter and each beam exceeding 1 mm at one institution for Varian and nine institutions for Elekta.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!