Validation of gel-free, label-free quantitative proteomics approaches: applications for seed allergen profiling.

J Proteomics

Department of Biochemistry, Interdisciplinary Plant Group, 109 Christopher S Bond Life Science Center, University of Missouri, Columbia, MO 65211, USA.

Published: April 2009

Plant seeds provide a significant portion of the protein present in the human diet, but are also the major contributors of allergenic proteins that cause a majority of the reported cases of food-induced anaphylaxis. New varieties of grains and nuts as well as other seeds could be screened for allergen content before they are introduced as cultivars for food production using mass spectrometry-based quantitation approaches. Here, we present a practical comparison of gel-free and label-free methods, peak integration and spectral counting, using a linear trap mass spectrometer. The results show that both methods are linear and reproducible with protein standards from 5-200 ng, however, bioinformatic analysis for spectral counting is much simpler and therefore more amenable to high-throughput sample processing. We therefore applied spectral counting towards the analysis of transgenic peanut lines targeting the reduction of a prominent allergen. Spectral count analysis of an Ara h 2 (conglutin-7) RNA-silenced line confirmed reduction of this allergen as well as Ara h 6 (conglutin), which was further confirmed by quantitative immunoblotting. Other collateral changes include an increase in Ara h 10 (oleosin 1) in one of the three lines, a decrease in conarachin as well as increased 13-lipoxygenase and Ahy-3 (arachin) in two of three lines.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jprot.2008.11.005DOI Listing

Publication Analysis

Top Keywords

spectral counting
12
gel-free label-free
8
three lines
8
validation gel-free
4
label-free quantitative
4
quantitative proteomics
4
proteomics approaches
4
approaches applications
4
applications seed
4
allergen
4

Similar Publications

: The number of incidental renal lesions identified in CT scans of the abdomen is increasing. Objective: The aim of this study was to determine whether hyperdense renal lesions without solid components in a portal venous CT scan can be clearly classified as vascular or non-vascular by material decomposition into iodine and water. This retrospective single-center study included 26 patients (mean age 72 years ± 9; 16 male) with 42 hyperdense renal lesions (>20 HU) in a contrast-enhanced Photon-Counting Detector CT scan (PCD-CT) between May and December 2022.

View Article and Find Full Text PDF

Purpose: With the widespread introduction of dual energy computed tomography (DECT), applications utilizing the spectral information to perform material decomposition became available. Among these, a popular application is to decompose contrast-enhanced CT images into virtual non-contrast (VNC) or virtual non-iodine images and into iodine maps. In 2021, photon-counting CT (PCCT) was introduced, which is another spectral CT modality.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to evaluate whether the iodine contrast in blood and solid organs differs between men and women and to evaluate the effect of BMI, height, weight, and blood volume (BV) on sex-specific contrast in staging CT.

Materials And Methods: Patients receiving a venous-phase thoracoabdominal Photon-Counting Detector CT (PCD-CT) scan with 100- or 120-mL CM between 08/2021 and 01/2022 were retrospectively included in this single-center study. Image analysis was performed by measuring iodine contrast in the liver, portal vein, spleen, left atrium, left ventricle, pulmonary trunk, ascending and descending aorta on spectral PCD-CT datasets.

View Article and Find Full Text PDF

Liquid chromatography coupled to high-resolution mass spectrometry (LC-HRMS) is commonly used for identification of compounds in complex samples due to the high chromatographic and mass spectral resolution provided. In subsequent data processing workflows, it is imperative to preserve this resolution to fully exploit the data. "Region of interest" (ROI) algorithms were introduced as a better alternative to equidistant binning for compressing HRMS data because they better preserve the mass spectral resolution.

View Article and Find Full Text PDF

Seafood quality preservation remains a critical focus in the food industry, particularly as the freeze-thaw process significantly impacts the freshness and safety of aquatic products. This study investigated quality changes in frozen mackerel subjected to two thawing methods, room temperature (RT) and running water (WT), and assessed the potential of hyperspectral imaging (HSI) for classifying these methods. After thawing, mackerel samples were stored at 5 °C for 21 days, with physicochemical, textural, and spectroscopic analyses tracking quality changes and supporting the development of a spectroscopic classification model.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!