Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: The usability of dental computer-based patient record (CPR) systems has not been studied, despite early evidence that poor usability is a problem for dental CPR system users at multiple levels.
Methods: The authors conducted formal usability tests of four dental CPR systems by using a purposive sample of four groups of five novice users. The authors measured task outcomes (correctly completed, incorrectly completed and incomplete) in each CPR system while the participants performed nine clinical documentation tasks, as well as the number of usability problems identified in each CPR system and their potential relationship to task outcomes. The authors reviewed the software application design aspects responsible for these usability problems.
Results: The range for correctly completed tasks was 16 to 64 percent, for incorrectly completed tasks 18 to 38 percent and for incomplete tasks 9 to 47 percent. The authors identified 286 usability problems. The main types were three unsuccessful attempts, negative affect and task incorrectly completed. They also identified six problematic interface and interaction designs that led to usability problems.
Conclusion: The four dental CPR systems studied have significant usability problems for novice users, resulting in a steep learning curve and potentially reduced system adoption.
Clinical Implications: The significant number of data entry errors raises concerns about the quality of documentation in clinical practice.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2614265 | PMC |
http://dx.doi.org/10.14219/jada.archive.2008.0105 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!