Metal gaskets (Re, Ir, Inconel, or stainless steel) normally used to contain fluid samples in the hydrothermal diamond-anvil cell (HDAC) are sometimes undesirable due to possible contamination and to gasket deformation at high pressures and temperatures resulting in nonisochoric behavior. Furthermore, in x-ray spectroscopic experiments, metal gaskets may attenuate the incident x-ray beam and emitted fluorescence x-rays, and the interaction of scattered radiation with the gasket may produce fluorescence that interferes with the x-ray spectrum of the sample. New arrangements and procedures were tested for the operation of the HDAC without using the metal gaskets. Distilled, de-ionized water was loaded into the sample chamber, a laser-milled recess 300 microm in diameter and approximately 50 microm deep centered in the 1.0 mm face of the lower diamond anvil, and sealed by pressing the top diamond anvil face directly against the lower one without a metal gasket in between. A maximum sample pressure of 202 MPa at 617 degrees C was maintained for a duration of 10 min without evidence of leakage. A small change in fluid density was observed in one experiment where the sample was held at 266 MPa at 708 degrees C for 10 min. The gasketless HDAC was also employed in x-ray absorption spectroscopy experiments, where, in addition to the sample chamber in the lower diamond, two grooves were milled at a 90 degrees angle to each other around the sample chamber to minimize the attenuation of incident and fluorescent x rays. With a minimum distance between the sample chamber and the grooves of 80 microm, a pressure of 76 MPa at 500 degrees C was maintained for 2 h with no change in the original fluid density.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.3013788DOI Listing

Publication Analysis

Top Keywords

metal gaskets
16
sample chamber
16
fluid samples
8
samples hydrothermal
8
hydrothermal diamond-anvil
8
diamond-anvil cell
8
lower diamond
8
diamond anvil
8
degrees maintained
8
fluid density
8

Similar Publications

Article Synopsis
  • - The study presents a new processing strategy for synchrotron scanning 3D X-ray diffraction data to analyze complex materials like crystalline rocks, focusing on overcoming challenges of deformation and multiple phases in the samples.
  • - The method utilizes Friedel pairs to accurately pinpoint diffraction events and employs new modules to match data, assign phases to pixels or voxels, and locally fit crystal orientations.
  • - Tests on fractured granite and a metal gasket demonstrate the technique's ability to detail internal structures and textures, revealing valuable information about materials under high plastic deformation.
View Article and Find Full Text PDF

Modelling of Fluid Permeability at the Interface of the Metal-to-Metal Sealing Surface.

Materials (Basel)

October 2024

Faculty of Mechanical Engineering and Mechatronics, West Pomeranian University of Technology in Szczecin, 19 Piastow Ave., 70-310 Szczecin, Poland.

This paper presents a method for modelling the permeability of fluid at the interface formed between flat parallel plates and the sharp-edged ridges of a metal gasket. This work was divided into three stages. In the first stage, numerical calculations simulating the deformation (compression of the gasket) were performed.

View Article and Find Full Text PDF

Indium seals have been used extensively in ultra-high vacuum and cryogenic applications. Typically, these seals use indium alongside or in place of other metal gaskets in stainless-steel vacuum flanges, with some custom applications for flanges sealing directly with glass (optics or tubes). Here, we present the design and performance of three pressed indium seals (99.

View Article and Find Full Text PDF

The emerging field of optical magnetometry utilizing negative-charged nitrogen vacancy (NV-) centers provides a highly sensitive lab bench technique for spatially resolved physical property measurements. Their implementation in high pressure diamond anvil cell (DAC) environments will become common as other techniques are often limited due to the spatial constraints of the sample chamber. Apparatus and techniques are described here permitting for more general use of magnetic field measurements inside a DAC using continuous wave optical detected magnetic resonance in NV- centers in a layer of nanodiamonds.

View Article and Find Full Text PDF

Raman study of decomposition of Na-bearing carbonates in water fluid at high P-T parameters.

Spectrochim Acta A Mol Biomol Spectrosc

December 2024

Sobolev Institute of Geology and Mineralogy, Siberian Branch of Russian Academy of Sciences, prospect Acad. Koptyug 3, Novosibirsk, 630090, Russia.

The study of Na-carbonates stability and their transformations in aqueous carbonate fluid under high P-T conditions is relevant from the point of view of the understanding geochemical processes of the Na-assisted carbon circulation in the Earth's crust and subduction zones. In situ Raman study of Na-bearing carbonate-water-Fe-metal system in diamond anvil cell (DAC) at high P-T conditions revealed that carbonates decompose with abiogenic formation of formates and other organic compounds that differs from behavior of carbonates in dry system. XRD and FTIR methods have been used additionally to determine the phase composition.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!