Tissue engineering often involves seeding cells into porous scaffolds and subjecting the scaffold to mechanical stimulation. Current experimental techniques have provided a plethora of data regarding cell responses within scaffolds, but the quantitative understanding of the load transfer process within a cell-seeded scaffold is still relatively unknown. The objective of this work was to develop a finite element representation of the transient and heterogeneous nature of a cell-seeded collagen-GAG-scaffold. By undertaking experimental investigation, characteristics such as scaffold architecture and shrinkage, cellular attachment patterns, and cellular dimensions were used to create a finite element model of a cell-seeded porous scaffold. The results demonstrate that a very wide range of microscopic strains act at the cellular level when a sample value of macroscopic (apparent) strain is applied to the collagen-GAG-scaffold. An external uniaxial strain of 10% generated a cellular strain as high as 49%, although the majority experienced less than approximately 5% strain. The finding that the strain on some cells could be higher than the macroscopic strain was unexpected and proves contrary to previous in vitro investigations. These findings indicate a complex system of biophysical stimuli created within the scaffolds and the difficulty of inducing the desired cellular responses from artificial environments. Future in vitro studies could also corroborate the results from this computational prediction to further explore mechanoregulatory mechanisms in tissue engineering.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1115/1.2979873 | DOI Listing |
Mater Horiz
January 2025
School of Materials Science and Engineering, Shaanxi University of Science and Technology, Xi'an 710021, P. R. China.
Multilayer thin films composed of dielectric BaCaZrTiO (BCZT) and oxygen-deficient BCZT (BCZT-OD) were fabricated on (001)-oriented NSTO substrates using the pulsed laser deposition (PLD) technique. Unlike conventional approaches to energy storage capacitors, which primarily focus on compositional or structural modifications, this study explored the influence of the layer sequence and periodicity. The interface between the NSTO substrate and the BCZT-OD layer forms a Schottky barrier, resulting in electric field redistribution across the sublayers of the BCZT/BCZT-OD//(1P) thin film.
View Article and Find Full Text PDFHeliyon
January 2025
Chalmers University of Technology, Department of Chemistry and Chemical Engineering, Kemivägen 10, 41296 Gothenburg.
Bulky cellulosic network structures (BRC) with densities between 60 and 130 g/l were investigated as a sustainable alternative to fossil-based foams for impact liners in bicycle helmets. The mechanical properties of BRC foams were characterized across a wide range of strain rates and incorporated into a validated finite element model of a hardshell helmet. Virtual impact tests simulating both consumer information and certification scenarios were conducted to compare BRC-lined helmets against conventional expanded polystyrene (EPS) designs.
View Article and Find Full Text PDFJ Biomech Eng
January 2025
School of Aerospace and Mechanical Engineering, University of Oklahoma, 865 Asp Ave, Norman, OK 73019, USA.
Hearing loss is highly related to acoustic injuries and mechanical damage of ear tissues. The mechanical responses of ear tissues are difficult to measure experimentally, especially cochlear hair cells within the organ of Corti (OC) at microscale. Finite element (FE) modeling has become an important tool for simulating acoustic wave transmission and studying cochlear mechanics.
View Article and Find Full Text PDFJ Biomech Eng
January 2025
Human-Centric Design Research Lab, Department of Mechanical Engineering, Texas Tech University, Lubbock, TX 79409, USA.
This study presents a comprehensive finite element model for the human wrist, constructed from a CT scan of a 68-year-old male (type I wrist). This model intricately captures the bone and soft tissue geometries to study the biomechanics of wrist axial loading through tendon-driven simulations and grasping biomechanics using metacarpal loads. Validation is carried out by assessing the radial and ulnar axial loading distribution, radiocarpal articulation contact patterns, and other standard finite element metrics.
View Article and Find Full Text PDFAnn Biomed Eng
January 2025
Department of Biomedical Engineering, Schulich School of Engineering, University of Calgary, CCIT216, 2500 University Drive NW, Calgary, AB, T2N 1N4, Canada.
Purpose: Simulation studies, such as finite element (FE) modeling, offer insights into knee joint biomechanics, which may not be achieved through experimental methods without direct involvement of patients. While generic FE models have been used to predict tissue biomechanics, they overlook variations in population-specific geometry, loading, and material properties. In contrast, subject-specific models account for these factors, delivering enhanced predictive precision but requiring significant effort and time for development.