An automated submicron beam profiler for characterization of high numerical aperture optics.

Rev Sci Instrum

Centre for Quantum Dynamics, Griffith University, Queensland, Brisbane 4111 Australia.

Published: September 2008

An automated, interferometrically referenced scanning knife-edge beam profiler with submicron resolution is demonstrated by directly measuring the focusing properties of three aspheric lenses with numerical aperture (NA) between 0.53 and 0.68, with spatial resolution of 0.02 microm. The results obtained for two of the three lenses tested were in agreement with paraxial Gaussian beam theory. It was also found that the highest NA aspheric lens, which was designed for 830 nm, was not diffraction limited at 633 nm. This process was automated using motorized translation stages and provides a direct method for testing the design specifications of high numerical aperture optics.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.2991112DOI Listing

Publication Analysis

Top Keywords

numerical aperture
12
beam profiler
8
high numerical
8
aperture optics
8
automated submicron
4
submicron beam
4
profiler characterization
4
characterization high
4
optics automated
4
automated interferometrically
4

Similar Publications

Integrated Modeling and Target Classification Based on mmWave SAR and CNN Approach.

Sensors (Basel)

December 2024

Wireless Sensing and Imaging Laboratory & 6G Research Laboratory, SRM University AP, Amaravati 522502, India.

This study presents a numerical modeling approach that utilizes millimeter-wave (mm-Wave) Frequency-Modulated Continuous-Wave (FMCW) radar to reconstruct and classify five weapon types: grenades, knives, guns, iron rods, and wrenches. A dataset of 1000 images of these weapons was collected from various online sources and subsequently used to generate 3605 samples in the MATLAB (R2022b) environment for creating reflectivity-added images. Background reflectivity was considered to range from 0 to 0.

View Article and Find Full Text PDF

Sampling is a pivotal element in the design of metasurfaces, enabling a broad spectrum of applications. Despite its flexibility, sampling can result in reduced efficiency and unintended diffractions, which are more pronounced at high numerical aperture or shorter wavelengths, e.g.

View Article and Find Full Text PDF
Article Synopsis
  • Methanol is a toxic substance used in industrial applications, while ethanol is safe for consumption and commonly found in beverages and antiseptics.
  • A new Photonic Crystal Fiber (PCF) sensor has been developed to accurately detect both methanol and ethanol, achieving high relative sensitivities of 95.72% and 97.55%, respectively.
  • This sensor offers exceptional precision and low material loss, enhancing safety monitoring and quality control in industries that use these substances.
View Article and Find Full Text PDF

Terahertz (THz) lens constitutes a vital component in the THz system. Metasurfaces-based THz metalenses and classical bulky lenses are severely constrained by chromatic/ spherical aberration and the diffraction limit. Consequently, achromatic super-resolution THz lenses are urgently needed.

View Article and Find Full Text PDF

Spatially selective imaging (SSI) involves sampling a group of pixels from different positions on an encoded object to display a decoded image. Here, SSI is achieved by using off-axis cylindrical Fresnel lens arrays to decode multiple images from an encoded print of structural color pixels. Each image is optically retrieved by separately placing different "keys" (arrays of lenses in different pseudorandom configurations) over the same encoded print, and then each image is digitally reconstructed for visualization.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!