A novel method for determining whole house particle removal and clean air delivery rates attributable to central and portable ventilation/air cleaning systems is described. The method is used to characterize total and air-cleaner-specific particle removal rates during operation of four in-duct air cleaners and two portable air-cleaning devices in a fully instrumented test home. Operation of in-duct and portable air cleaners typically increased particle removal rates over the baseline rates determined in the absence of operating a central fan or an indoor air cleaner. Removal rates of 0.3- to 0.5-microm particles ranged from 1.5 hr(-1) during operation of an in-duct, 5-in. pleated media filter to 7.2 hr(-1) for an in-duct electrostatic air cleaner in comparison to a baseline rate of 0 hr(-1) when the air handler was operating without a filter. Removal rates for total particulate matter less than 2.5 microm in aerodynamic diameter (PM2.5) mass concentrations were 0.5 hr(-1) under baseline conditions, 0.5 hr(-1) during operation of three portable ionic air cleaners, 1 hr(-1) for an in-duct 1-in. media filter, 2.4 hr(-1) for a single high-efficiency particle arrestance (HEPA) portable air cleaner, 4.6 hr(-1) for an in-duct 5-in. media filter, 4.7 hr(-1) during operation of five portable HEPA filters, 6.1 hr(-1) for a conventional in-duct electronic air cleaner, and 7.5 hr(-1) for a high efficiency in-duct electrostatic air cleaner. Corresponding whole house clean air delivery rates for PM2.5 attributable to the air cleaner independent of losses within the central ventilation system ranged from 2 m3/min for the conventional media filter to 32 m3/min for the high efficiency in-duct electrostatic device. Except for the portable ionic air cleaner, the devices considered here increased particle removal indoors over baseline deposition rates.

Download full-text PDF

Source
http://dx.doi.org/10.3155/1047-3289.58.11.1474DOI Listing

Publication Analysis

Top Keywords

air cleaner
28
particle removal
20
removal rates
16
media filter
16
air
14
clean air
12
air delivery
12
delivery rates
12
operation in-duct
12
air cleaners
12

Similar Publications

Environmental pollution, stemming from the disposal of contaminants, poses severe threats to ecosystems and human health. The emergence of a new class of pollutants, termed emerging contaminants (ECs), in soil, water, and air has raised global concerns, aligning with the UN 2030 Agenda's Sustainable Development Goals. Aerogels, three-dimensional structures with high porosity and low density, offer promise in addressing this issue.

View Article and Find Full Text PDF

This research marks the inaugural endeavor in Gilgit-Baltistan (GB) to identify the primary sources of household energy and indoor air pollutants (IAPs) during the winter and additionally, to evaluate the health impacts associated with IAPs within specific high-altitude communities in Gilgit-Baltistan, Pakistan. Using the convenience sampling method, 20 households were continuously monitored to assess IAPs based on standards time-weighted average. The study found that 90% of the population relied primarily on animal dung as their main energy source, with wood, agricultural residues, electricity, and gas as other sources.

View Article and Find Full Text PDF

This study addresses the challenge of reducing "net" toxic pollutant discharge, specifically dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), while minimizing the energy consumption and costs associated with detoxification. Our research focuses on reintroducing fly ash and scrubber sludge (ASR) into a hazardous waste thermal treatment system equipped with gasification-intense low oxygen dilution (GASMILD) and an advanced air pollution control system (APCS). This approach yielded a remarkable PCDD/F removal efficiency exceeding 99.

View Article and Find Full Text PDF

Towards healthy sleep environments: Ambient, indoor, and personal exposure to PM and its implications in children's sleep health.

Environ Res

January 2025

Department of Civil, Environmental, & Architectural Engineering, Worcester Polytechnic Institute, Worcester, MA, United States. Electronic address:

The growing impact of climate change and escalating wildfire seasons has led to heightened ambient air pollution, potentially affecting children's sleep health. However, current epidemiological research often relies on outdoor weather data to model the environmental impacts on sleep health, potentially mischaracterizing the actual bedroom environment. To address these challenges, we conducted experiments to investigate the relationships among ambient, indoor, and personal exposure to PM concentrations and obstructive sleep apnea (OSA) in children.

View Article and Find Full Text PDF

Science tells us that portable air filters reduce infection risk. It's time for public health authorities to make this clear.

J Infect Public Health

January 2025

Dalla Lana School of Public Health, University of Toronto, 155 College St., Toronto, Ontario M5T 3M7, Canada; Department of Civil & Mineral Engineering, 35 St. George St, Toronto, Ontario M5S 1A4, Canada.

Throughout the COVID-19 pandemic, Canadian public health advisors and politicians have shared mixed messages about the utility of portable air filters (PAFs) for mitigating the transmission of airborne infectious diseases. Some public health advisors and decision-makers have also suggested that PAFs are cumbersome or require expert advice. We take this opportunity to review evidence and address myths about PAFs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!