[Ultrasensitive TSH and thyroliberin test in patients hospitalized for depression].

Rev Med Interne

Service de Médecine Interne, Hôpital Jean Verdier, Bondy.

Published: July 1991

In this prospective study of 35 patients hospitalized for depression, TSH levels were measured before and after stimulation by TRH. The type of depression was determined and its intensity was evaluated by means of the HARD scale. Subjects with systemic disease or receiving treatments known as being likely to influence TSH levels had been excluded. In none of these 35 patients was the TSH level below the lower limit of normal values, nor was there any blunting of response to TRH. These results suggest that depression is not a cause of TSH fall and that a low TSH level with normal hormonaemia must call for scintiscanning, even in depressed subjects.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0248-8663(05)81348-7DOI Listing

Publication Analysis

Top Keywords

patients hospitalized
8
depression tsh
8
tsh levels
8
tsh level
8
tsh
5
[ultrasensitive tsh
4
tsh thyroliberin
4
thyroliberin test
4
test patients
4
hospitalized depression]
4

Similar Publications

Objectives: Despite the advances in medicine, aortic dissection remains a cardiac surgery emergency with high mortality and morbidity rates. This study examined the effects of the Glue + Felt technique, which uses biological glue and felt to repair the proximal anastomotic site, on the outcomes of patients with acute type A aortic dissection.

Methods: A total of 108 patients who underwent surgery for acute type A aortic dissection at our clinic between 2007 and 2020 were included in the study.

View Article and Find Full Text PDF

Introduction And Objectives: High flow nasal cannula (HFNC) therapy is an increasingly popular mode of non-invasive respiratory support for the treatment of patients with acute hypoxemic respiratory failure (AHRF). Previous experimental studies in healthy subjects have established that HFNC generates flow-dependent positive airway pressures, but no data is available on the levels of mean airway pressure (mP) or positive end-expiratory pressure (PEEP) generated by HFNC therapy in AHRF patients. We aimed to estimate the airway pressures generated by HFNC at different flow rates in patients with AHRF, whose functional lung volume may be significantly reduced compared to healthy subjects due to alveolar consolidation and/or collapse.

View Article and Find Full Text PDF

The influence of sintering of osteoporotic vertebral fractures on the sagittal lumbar profile and degenerative changes.

J Orthop Surg Res

January 2025

Department of Orthopaedic and Trauma Surgery, Medical Faculty, University Hospital Düsseldorf, Heinrich-Heine-University, Düsseldorf, Germany.

Background: Osteoporosis, a skeletal disorder affecting nearly 20% of the global population, poses a significant health concern, with osteoporotic vertebral body fractures (VBF) representing a common clinical manifestation. The impact of osteoporotic sintering fractures in the thoracolumbar spine on the sagittal lumbar profile is incompletely understood and may lead to the onset of clinical symptoms in previously asymptomatic patients.

Methods: This retrospective single-center study analyzed data from patients presenting with osteoporotic spine fractures between 2017 and 2022.

View Article and Find Full Text PDF

Background: Near-infrared spectroscopy (NIRS) enables a non-invasive measurement of tissue oxygen saturation (StO) in regions illuminated by near-infrared lights. Vascular occlusion test (VOT) serves as a model to artificially induce forearm ischemia-reperfusion. The combination of StO monitoring and VOT allows for dynamic evaluation of the balance between oxygen delivery and consumption in tissue, as well as the functional reserve of microcirculation.

View Article and Find Full Text PDF

Implant failure of the Compress prosthesis: a case report.

J Med Case Rep

January 2025

Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, Nagoya University Hospital, 65 Tsurumai, Showa, Nagoya, Aichi, 466-8550, Japan.

Background: The Compress is designed to achieve bone formation and stability by applying pressure at the bone-implant interface, minimizing the likelihood of aseptic loosening, which is a complication of stem implants. Herein, we report two cases of implant failure using the Compress.

Case Presentation: Case 1 describes a 36 year-old Japanese man who underwent extraarticular tumor resection, Compress arthroplasty, and reconstruction with a gastrocnemius flap after preoperative chemotherapy for a secondary malignant giant cell tumor in the right distal femur.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!