Introduction: We have previously shown that a vesico-amniotic shunt (V-A shunt) produces fibrotic bladders with poor compliance in normal fetal lambs. We hypothesized that using a ventriculo-peritoneal shunt (V-P shunt) as a V-A shunt in normal bladders may preserve the filling/emptying cycle and normal bladder development.

Materials And Methods: The V-A shunting in normal fetal lambs was performed at 74 days of gestation using a V-P shunt (group A) and a free-draining shunt tube (group B). Sham-operated lambs were used as controls (group C). They were all delivered at term (145 days), and the pressure-volume curve, bladder volume, and histologic features of the bladder wall were compared.

Result: The mean bladder volume in group B (n = 5), 5 +/- 2.4 mL, was significantly smaller (P < .01) than that in group A (n = 6), 53 +/- 14 mL, and group C (n = 10), 57.3 +/- 12 mL. The bladder wall thickness in group A was 338 + 94.2 microm; group B, 741 +/- 128 microm; and group C, 374 +/- 120 microm. Group B bladders had very poor compliance with thick bladder wall (P < .01). Histologically, group B bladders showed prominent submucosal fibrotic change, but group A bladders were similar to controls.

Conclusion: This study shows that a pressure-limited shunt tube for V-A shunting preserves the normal fetal bladder development.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpedsurg.2008.08.058DOI Listing

Publication Analysis

Top Keywords

shunt tube
12
normal fetal
12
group
12
bladder wall
12
microm group
12
group bladders
12
shunt
9
vesico-amniotic shunt
8
bladder
8
normal bladder
8

Similar Publications

Purpose: To assess the safety and efficacy of a modified suprachoroidal silicone tube (SST) shunt in patients with primary open-angle glaucoma (POAG) and pseudo-exfoliative glaucoma (PXG) in this experimental study.

Methods: In this single-center, retrospective longitudinal data analysis 66 eyes of 59 patients having POAG and PXG were included and treated with modified SST shunt in combination with cataract or as a stand-alone procedure. Pre- and postoperative intraocular pressure (IOP), best corrected visual acuity (BCVA), C/D ratio and ocular adverse events (AEs) were assessed in all participants.

View Article and Find Full Text PDF

To explore techniques, advantages and disadvantages of 3D Slicer reconstruction and 3D printing localization technology combined with transcranial neuroendoscopy in ventriculoperitoneal shunt surgery. Retrospective analysis of clinical data of patients with hydrocephalus treated by ventriculoperitoneal shunt surgery using 3D Slicer reconstruction and 3D printing positioning technology combined with transcranial neuroendoscopy in our hospital from October 2021 to March 2023. A total of 33 patients with complete data were collected, including 19 males and 14 females, aged 10-81 years.

View Article and Find Full Text PDF

Coats disease presenting with vitreous hemorrhage and neovascular glaucoma.

Am J Ophthalmol Case Rep

March 2025

Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Chicago, 60612, USA.

Purpose: To describe a patient with Coats disease with an atypical presentation of neovascular glaucoma and vitreous hemorrhage.

Observations: A 15-year-old male presented with five days of pain, redness, and swelling and was found to have neovascular glaucoma in his right eye. Further evaluation revealed Coats disease stage 3AI with a subtotal exudative retinal detachment inferiorly, telangiectatic vessels, and vitreous hemorrhage.

View Article and Find Full Text PDF

: To report the role of prostaglandin-associated periorbitopathy (PAP) severity on the surgical efficacy of Ahmed Glaucoma Valve (AGV) implantation. : Retrospective observational case series. Participants were the consecutive 102 eyes from 102 Japanese subjects (55 males, 47 females; mean age ± standard deviation, 74.

View Article and Find Full Text PDF

New treatments for glaucoma.

Curr Opin Ophthalmol

January 2025

New York Eye Surgery Center, New York City, New York, USA.

Purpose Of Review: This review highlights new Federal Drug Administration (FDA) approved glaucoma treatments to familiarize providers with immediately available options.

Recent Findings: New FDA-approved treatments include the bimatoprost implant, travoprost implant, direct selective laser trabeculoplasty (DSLT), and ocular pressure adjusting pump. The bimatoprost implant is approved for a single administration with effects lasting for about 1 year, as opposed to the nearly 3-year effect for the travoprost implant.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!