Biomechanical factors in human dermal bitemarks in a cadaver model.

J Forensic Sci

Laboratory for Forensic Odontology Research, School of Dental Medicine, SUNY at Buffalo, B1 Squire Hall, South Campus, Buffalo, NY 14214, USA.

Published: January 2009

In bitemark analysis, the forensic odontologist must consider how the biomechanical properties of the skin contribute to distortion of the bitemark. In addition, one must consider how the bitemark can be distorted by postural movement of the victim after the bite has occurred. A fundamental review of the architecture and biomechanical properties of the dermis is described and evaluated through bites made on cadavers. In order to assess distortion, 23 bites from a single characterized dentition were made on un-embalmed cadaver skin. Bite indentations were photographed. Following various body manipulations they were re-photographed in different positions. Hollow volume overlays of the biting dentition were constructed, and metric analysis of the dentition and all bitemarks was completed. The overall intercanine, mesial to distal, and angle of rotation distortion was calculated. Of the 23 bites made, none were measurably identical, and in some cases, dramatic distortion was noted.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1556-4029.2008.00908.xDOI Listing

Publication Analysis

Top Keywords

biomechanical properties
8
biomechanical factors
4
factors human
4
human dermal
4
dermal bitemarks
4
bitemarks cadaver
4
cadaver model
4
model bitemark
4
bitemark analysis
4
analysis forensic
4

Similar Publications

MR Elastography Using the Gravitational Transducer.

Sensors (Basel)

December 2024

Research Department of Imaging Physics and Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London WC2R 2LS, UK.

MR elastography is a non-invasive imaging technique that provides quantitative maps of tissue biomechanical properties, i.e., elasticity and viscosity.

View Article and Find Full Text PDF

Kinematic assessment of ball kicking may require significant human effort (e.g., traditional vision-based tracking systems).

View Article and Find Full Text PDF

Effect of Sr on Mechanical Properties and Corrosion Behavior of Rolled ZM60 Alloy.

Materials (Basel)

December 2024

School of Materials Science and Engineering, Jiamusi University, Jiamusi 154000, China.

Mg-6Zn-0.5Mn as a medical magnesium alloy has good biomechanical properties and corrosion resistance, but as a fracture internal-fixation material, its strength, toughness, and corrosion resistance still need to be improved. In this paper, the element Sr, having good biocompatibility, is used as an alloy element.

View Article and Find Full Text PDF

The use of motorized nickel titanium instruments is an essential component in contemporaneous clinical endodontics. The mechanical properties of nickel titanium are optimal for the cleaning and shaping of root canal systems. However, instrumentation carries risks, particularly instrument fracture, which may become an obstacle to achieving adequate disinfection of the canal system.

View Article and Find Full Text PDF

Fibrotic cardiomyopathy represents a significant pathological condition characterized by the interaction between cardiomyocytes and fibroblasts in the heart, and it currently lacks an effective cure. In vitro platforms, such as engineered heart tissue (EHT) developed through the co-culturing of cardiomyocytes and fibroblasts, are under investigation to elucidate and manipulate these cellular interactions. We present the first integration of mathematical electrophysiological models that encapsulate fibroblast-cardiomyocyte interactions with experimental EHT studies to identify and modulate the ion channels governing these dynamics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!