Objective: To determine if a combination of ferucarbotran-enhanced T2*weighted-gradient echo (T2*W-GRE) and T2-weighted turbo spin echo (T2W-TSE) images in gadolinium- and ferucarbotran-enhanced MRI has additive efficacy compared to each image alone for detecting small (< or = 2.0 cm) hepatocellular carcinoma (HCC) lesions in a group of cirrhotic patients and metastases in a group of non-cirrhotic patients.

Materials And Methods: Two readers retrospectively analyzed gadolinium- and ferucarbotran-enhanced T2*W-GRE, T2W-TSE, and combined T2*W-GRE/T2W-TSE images of 119 patients with 157 HCCs and 32 patients with 98 metastases. The diagnostic accuracy and sensitivity for each image set and the combined set were evaluated using the alternative-free response receiver operating characteristic method.

Results: The mean area under the curve value of the combined set (0.966) tended to be better than that for each individual image set (T2W-TSE [0.910], T2*W-GRE [0.892]). Sensitivities in the combined set were higher than those in each individual image set for detecting HCC (mean, 93.0% versus 81.6% and 86.7%, respectively, p < 0.01). Sensitivities in the combined set and the T2W-TSE set were the same for detecting metastases, and both were higher than the sensitivity seen in the T2*W-GRE set (mean, 97.5% versus 85.2 %, p < 0.01).

Conclusion: Combining ferucarbotran-enhanced T2*W-GRE and T2W-TSE has additive efficacy for detecting HCC in cirrhotic patients, but T2W-TSE is preferred for detecting metastases in non-cirrhotic patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2627240PMC
http://dx.doi.org/10.3348/kjr.2008.9.6.510DOI Listing

Publication Analysis

Top Keywords

combined set
16
gadolinium- ferucarbotran-enhanced
12
image set
12
set
9
combining ferucarbotran-enhanced
8
t2-weighted turbo
8
turbo spin
8
spin echo
8
additive efficacy
8
cirrhotic patients
8

Similar Publications

We report nonadiabatic dynamics computations on CH initiated on a coherent superposition of the five lowest cationic states, employing the Quantum Ehrenfest method. In addition to the totally symmetric carbon-carbon double bond stretch and carbon-hydrogen stretches, we see that the three non-totally symmetric modes become stimulated; torsion and three different CH stretching patterns. Thus, a coherent superposition of states, of the type involved in an attochemistry experiment, leads to the stimulation of specific non-totally symmetric motions.

View Article and Find Full Text PDF

Introduction: Shoulder stabilization surgery is common among military personnel, causing severe acute postoperative pain that may contribute to the development of chronic pain, thereby reducing military readiness. Battlefield Acupuncture (BFA) has shown promise as a non-pharmaceutical intervention for acute postoperative pain. The purpose of this study was to determine the effectiveness of BFA combined with standard physical therapy on pain, self-reported mood, self-reported improvement, and medication use in patients after shoulder stabilization surgery.

View Article and Find Full Text PDF

: Splenectomy leads to a high rate of remission in chronic primary immune thrombocytopenia (ITP), but its unpredictable long-term positive outcomes and that it is a irreversible surgical approach discourage clinicians and patients. The identification of predictors of response may redefine the timing of splenectomy. In this retrospective, multicentric study we aimed to investigate clinical-histological predictors of splenectomy response in ITP patients and provide an easy-to-use score to predict splenectomy response in ITP.

View Article and Find Full Text PDF

Validation of Aerobic Capacity (VO2max) and Pulse Oximetry in Wearable Technology.

Sensors (Basel)

January 2025

School of Integrated Health Sciences, Department of Kinesiology and Nutrition Sciences, University of Nevada, Las Vegas, NV 89154, USA.

Introduction: As wearable technology becomes increasingly popular and sophisticated, independent validation is needed to determine its accuracy and potential applications. Therefore, the purpose of this study was to evaluate the accuracy (validity) of VO2max estimates and blood oxygen saturation measured via pulse oximetry using the Garmin fēnix 6 with a general population participant pool.

Methods: We recruited apparently healthy individuals (both active and sedentary) for VO2max (n = 19) and pulse oximetry testing (n = 22).

View Article and Find Full Text PDF

Fibre Optic Method for Detecting Oil Fluorescence in Marine Sediments.

Sensors (Basel)

December 2024

Department of Operational Oceanography, Maritime Institute, Gdynia Maritime University, ul. Roberta de Plelo 20, 80-848 Gdańsk, Poland.

The aim of this study is to verify the possibility of detecting oil in the bottom sediment using a fibre optic system. The presence of oil is assessed on excitation-emission spectra obtained from spectral fluorescence signals of the sediment sample. A factory spectrofluorometer coupled with an experimental fibre optic measurement system was used.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!