Unlabelled: CT-based attenuation correction (AC) for myocardial perfusion PET studies is challenging because of respiratory motion. Our study aimed to compare the transmission CT (TCT)-based and CT-based AC for myocardial perfusion PET/CT images with a direct semiquantitative approach comparing differences in segmental count distribution.
Methods: Stress and rest (82)Rb PET scans from 54 consecutive patients acquired on a PET/CT scanner with dual CT-based and TCT-based AC were considered. TCT- and CT-based AC images were automatically registered to each other, and direct voxel-based and American Heart Association segment-based estimation of positive and negative changes between these scans was performed. Additionally, visual quality control (QC) of CT map alignment with PET emission data was performed by 2 expert observers, and studies with significant (>/=5 mm) misalignment were reprocessed with corrected CT alignment.
Results: We used the 17-segment American Heart Association model for TCT-to-CT regional change analysis in all patients and found that 4 segments on rest and 4 segments on stress scans differed more than 3% between CT- and TCT-corrected images for studies without significant misalignments (<5 mm); only 1 differed by more than 5%. In cases with significant misalignment of greater than or equal to 3% TCT-CT AC, changes were observed on 14 rest and 10 stress segments; after alignment, these differences were still seen in 13 rest segments and 11 stress segments. Visual QC revealed that 46% of rest and 54% of stress PET scans were misaligned by greater than or equal to 5 mm with the CT maps acquired during normal breathing. The range of the reported PET/CT misalignment was 0-15 mm in x, 0-16 mm in y, and 0-20 mm in z directions. The overall agreement in visual QC of PET/CT alignment between the observers was 72.2%
Conclusion: There are significant differences between TCT and CT AC applied to cardiac PET/CT studies, which remain after alignment of CT maps to emission data.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2967/jnumed.108.056580 | DOI Listing |
PLoS One
January 2025
Electrical, Mechanical & Computer Engineering School, Federal University of Goias, Goiania, Brazil.
This paper proposes the use of artificial intelligence techniques, specifically the nnU-Net convolutional neural network, to improve the identification of left ventricular walls in images of myocardial perfusion scintigraphy, with the objective of improving the diagnosis and treatment of coronary artery disease. The methodology included data collection in a clinical environment, followed by data preparation and analysis using the 3D Slicer Platform for manual segmentation, and subsequently, the application of artificial intelligence models for automated segmentation, focusing on the efficiency of identifying the walls of the left ventricular. A total of 83 clinical routine exams were collected, each exam containing 50 slices, which is 4,150 images.
View Article and Find Full Text PDFCurr Cardiol Rep
January 2025
Department of Cardiovascular Disease, Mayo Clinic, Rochester, MN, USA.
Purpose Of Review: Critical Care Echocardiography (CCE) is now established as an important tool in the intensive care unit (ICU). This paper aims to examine the expanding role of cardiovascular ultrasound in the ICU, focusing on its applications, benefits, and challenges, while highlighting recent advancements shaping the future of critical care echocardiography.
Recent Findings: Non-invasive echocardiographic measurement of hemodynamic parameters including stroke volume, cardiac output, left ventricular filling pressures, and pulmonary pressures have been well-validated against invasive measurements.
J Nucl Med
January 2025
Milstein Division of Cardiology, Department of Medicine, Columbia University Irving Medical Center, NewYork-Presbyterian Hospital, New York, New York;
Cardiac allograft vasculopathy (CAV) causes impaired blood flow in both epicardial vessels and microvasculature and remains a leading cause of posttransplant morbidity and mortality. This study examined the prognostic value and outcomes of CAV, assessed by N-ammonia PET/CT myocardial perfusion imaging in heart transplant recipients. PET/CT and invasive coronary angiography (ICA) were graded using validated scales.
View Article and Find Full Text PDFHeart
January 2025
Cardiology, University Hospital of Copenhagen, Copenhagen, Denmark.
Acute myocardial infarction-related cardiogenic shock (AMI-CS) is a severe, life-threatening condition characterised by inadequate tissue perfusion due to the heart's inability to pump blood effectively. The pathophysiology of AMI-CS usually arises from the sudden loss of myocardial contractility, leading to a decrease in cardiac output and systemic hypoperfusion. In approximately 90% of AMI-CS cases, the left ventricle is the primary site of dysfunction.
View Article and Find Full Text PDFCurr Pediatr Rep
May 2024
Coronary Artery Anomalies Program, Division of Cardiology, Texas Children's Hospital, 6651 Main Street MC-E1920, Houston, TX 77030 USA.
Purpose Of Review: We present a contemporary approach to risk assessment and management of patients with anomalous aortic origin of a coronary artery (AAOCA).
Recent Findings: Anomalous left coronary artery from the right aortic sinus (L-AAOCA) with interarterial course carries a high risk of sudden cardiac death (SCD); therefore, current guidelines recommend exercise restriction and surgical intervention. Recent data in intraseptal and juxtacommissural L-AAOCA showed inducible perfusion abnormalities, leading to consideration of surgical intervention.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!