A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Endothelial keratoplasty: the influence of preoperative donor endothelial cell densities on dislocation, primary graft failure, and 1-year cell counts. | LitMetric

Purpose: The purpose of this study was to determine if an association exists between preoperative donor central endothelial cell density (ECD) and the complications of donor dislocation, iatrogenic primary graft failure (IPGF), and endothelial survival at 1 year after endothelial keratoplasty (EK) surgery.

Methods: A prospective, nonrandomized, interventional case study was conducted evaluating 629 consecutive EK procedures. The preoperative donor ECD was recorded for each case. The mean preoperative ECD of the group of EK cases with postoperative donor dislocation was compared with the mean ECD of the group of EK cases that did not suffer donor dislocation. The subset of eyes that underwent Descemet stripping automated endothelial keratoplasty (DSAEK) was also evaluated for dislocation, IPGF, and ECD at 1 year.

Results: There were 31 eyes that suffered a dislocation in the overall group of 629 eyes (4.9% dislocation rate). The mean preoperative ECD of the donor tissue in this dislocation group was 2769 cells per square millimeter (range = 2147-3454 cells/mm). The mean preoperative ECD of the donor tissue in the group that did not dislocate (n = 598) was 2818 cells per square millimeter (range = 2110-4209 cells/mm). There was no significant difference in preoperative ECD between these groups (P = 0.428). There was a subset of 350 cases of DSAEK, of which 9 cases dislocated (2.6% dislocation rate). The mean preoperative ECD of the donor tissue in this dislocation group was 2604 cells per square millimeter (range = 2323-3175 cells/mm), with 5 of the 9 dislocation donors with a preoperative ECD above 2500 cells per square millimeter. The mean preoperative ECD of the donor tissue in the group that did not dislocate (n = 341) was 2825 cells per square millimeter (range = 2110-4209 cells/mm). There was no significant difference in preoperative ECD between these groups (P = 0.069). There was no significant correlation between preoperative ECD and the ECD at 1 year after DSAEK (n = 90; Pearson correlation = 0.184; P = 0.082). There were no IPGFs in the entire series of 350 consecutive DSAEK cases, and therefore, no statistical analysis is possible for IPGF.

Conclusions: Preoperative donor ECD was not associated with donor dislocation for any form of EK surgery. Tissue with donor cell counts below 2500 cells per square millimeter can attach, and tissue with donor cell counts above 2500 cells per square millimeter can detach. Higher preoperative donor ECD was not correlated with higher ECD at 1 year postoperatively. Surgeons' requests for donor tissue with an ECD above 2500 cells per square millimeter for DSAEK surgery for the purpose of avoiding dislocations, IPGF, or improving 1-year ECD are not supported by this data.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICO.0b013e3181814cbcDOI Listing

Publication Analysis

Top Keywords

preoperative ecd
36
cells square
32
square millimeter
32
preoperative donor
20
donor tissue
20
ecd
19
donor
16
donor dislocation
16
ecd donor
16
millimeter range
16

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!