Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: During the detection of neck recurrence in patients with Papillary Thyroid Carcinoma (PTC), sometimes it is difficult to distinguish metastatic from inflammatory neck lymph nodes. The measurement of serum thyroglobulin (sTg) under thyroid hormone suppression therapy the presence of serum thyroglobulin antibodies (sAbTg), the diagnostic whole body scan and cytology can give false negative results. Measurement of thyroglobulin in the washout fluid from fine-needle aspiration biopsy (FNAB) of suspicious neck lymph nodes could improve the diagnostic accuracy.
Aim: To evaluate the usefulness of detecting Tg in lymph nodes (LTg) suspicious by ultrasonography (US) and compare it to cytology.
Patients And Methods: Between the years 2004 and 2007 we prospectively studied 30 patients with PTC and cervical US findings of suspicious recurrence. LTg was assayed in US guided FNAB used for cytology.
Results: Sixteen out of 30 patients underwent surgery using as selective criteria an LTg higher than sTg or a positive cytology. Surgery confirmed the presence of metastasis in all 15 patients with positive LTg (8 with positive cytology) and in 1 patient with negative LTg and positive cytology (a case with undifferentiated thyroid cancer). The sensitivity was 93.7% for LTg and 56.2% for cytology. We identified by LTg 3 of 6 patients with undetectable sTg and positive sAbTg.
Conclusions: The presence of LTg showed a higher sensitivity than cytology for the detection of cervical lymph node metastasis. This method is useful even in the presence of sAbTg.
Download full-text PDF |
Source |
---|
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!