Purpose: To evaluate corneal viscoelastic and intraocular pressure (IOP) changes measured by an ocular response analyzer (ORA) after phacoemulsification and intraocular lens (IOL) implantation.
Setting: Yeditepe University Department of Ophthalmology, Istanbul, Turkey.
Methods: Fifty-one eyes scheduled for cataract surgery were included in the study. Corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated intraocular pressure (IOPcc), and Goldmann-correlated IOP (IOPg) were measured by ORA preoperatively and 1 week and 1 and 3 months postoperatively. Central corneal thickness (CCT) was measured using the ORA's integrated handheld ultrasonic pachymeter.
Results: The mean preoperative CCT (537 microm+/-46 [SD]) did not change significantly by the end of 1 month postoperatively. The mean preoperative IOPcc (17.2+/-3.0 mm Hg) decreased significantly by 3 months postoperatively (15.2+/-3.7 mm Hg) (P= .018). The mean CH decreased from 10.36+/-1.48 mm Hg preoperatively to 9.64+/-1.26 mm Hg at 1 week (P= .028); it increased to preoperative values at the end of 1 month (10.20+/-1.70) and 3 months (10.74+/-1.54) (P>.05). The mean CRF decreased from 10.94+/-2.54 mm Hg preoperatively to 9.99+/-1.77 at 1 week (P= .026); it increased to preoperative values at 1 month (10.26+/-1.59) and 3 months (10.35+/-1.46) (P>.05).
Conclusions: Although CH and the CRF decreased in the early postoperative period, the parameters increased and reached preoperative values by 3 months postoperatively, showing that corneal biomechanical properties are influenced by phacoemulsification and IOL implantation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jcrs.2008.08.017 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!