Background: Recent technological advancements in total ankle arthroplasty (TAA) have included the introduction of the mobile bearing concept. This bearing has several advantages, but researchers have questioned whether or not increased mobility sacrifices joint stability or durability of the implant. The present study evaluated the kinematics of this type of prosthesis implanted in patients.

Materials And Methods: Fluoroscopy and 3D-to-2D registration techniques were used to determine the in vivo kinematics for 20 TAA subjects performing two activities: gait and step-up. The motion of the prostheses was described in terms of clinical rotations and as rotation about the helical (screw) axis. Then, the anterior-posterior translation and axial rotation of the mobile bearing insert were determined.

Results: Among the clinical rotations, the dorsi-/plantarflexion was the most dominant, revealing the greatest pattern change and the largest magnitude. During gait, the orientation of the prosthetic components changed smoothly from plantarflexion to dorsiflexion. The average range of this motion was 9.2 degrees. For step-up activity, the range was 8.0 degrees. However, between 33% and 66% of stance phase, the talar component's orientation changed from dorsiflexion to plantarflexion. The average absolute range of anterior-posterior translation of the mobile bearing insert was 1.5 mm and 2.3 mm for gait and step-up, respectively.

Conclusion: These measured translations were relatively small and may suggest that the rotational portion of the motion was more dominant than translational and provided sufficient mobility.

Download full-text PDF

Source
http://dx.doi.org/10.3113/FAI.2008.1117DOI Listing

Publication Analysis

Top Keywords

mobile bearing
12
vivo kinematics
8
total ankle
8
gait step-up
8
clinical rotations
8
anterior-posterior translation
8
bearing insert
8
kinematics salto
4
salto total
4
ankle prosthesis
4

Similar Publications

Environmental impact of an acid-forming alum shale waste rock legacy site in Norway.

Environ Sci Process Impacts

January 2025

Environmental Chemistry Section, Faculty of Environmental Sciences and Natural Resource Management, Norwegian University of Life Sciences, Aas, Norway.

Alum shale formations in Scandinavia are generally enriched in uranium (U) and, when exposed to air and water, may produce acidic rock drainage (ARD), releasing potentially harmful elements into the environment. Taraldrud is a legacy site in southeast Norway where approx. 51 000 m of alum shale was deposited in the 1980s-1990s.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to compare the Modular Dual Mobility (MDM) hip system and large femoral heads (LFHs) in revision total hip arthroplasties (THAs), focusing on risks like dislocation and metal-related complications.
  • Researchers analyzed 299 revision THAs and found that the MDM group had a significantly lower rate of re-revision for dislocation (99% survival) compared to the LFH group (91% survival), with increased risks for LFH patients.
  • Overall, THAs utilizing the MDM construct demonstrated a safer profile, particularly in reducing re-revisions related to dislocation and had no reported issues with metallosis or corrosion.
View Article and Find Full Text PDF

Background: Total ankle arthroplasty (TAA) has been developed as treatment for disabling tibiotalar osteoarthritis. TAAs are divided into mobile- and fixed-bearings. The aim was to determine the incidence and trends of fixed- and mobile bearings over time and investigate the association of bearing type and risk of revision after primary TAA in the Netherlands.

View Article and Find Full Text PDF

Superior One-year Forgotten Joint Scores with cruciate-retaining mobile bearings versus posterior-stabilized mobile and fixed bearings in a contemporary total knee system.

Knee

December 2024

Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, South Korea; Department of Orthopaedic Surgery, Seoul National University Hospital, Seoul, South Korea. Electronic address:

Background: Total knee arthroplasty (TKA) mainly involves the femoral, tibial, and bearing implants. Bearings are categorized by posterior cruciate ligament (PCL) status (cruciate-retaining [CR] vs. posterior-stabilized [PS]) and motion (mobile vs.

View Article and Find Full Text PDF

Background: The presence of full-thickness cartilage in the lateral compartment on valgus stress radiography is a criterion for medial mobile-bearing unicompartmental knee arthroplasty (UKA). However, the appropriateness of medial UKA is uncertain when preoperative MRI shows extrusion of the lateral meniscus. We therefore assessed how preoperative MRI-detected lateral meniscus extrusion affects mid-term functional outcomes after mobile-bearing UKA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!