Simplex optimization of acoustic assay for plasminogen activators.

Anal Bioanal Chem

School of Engineering, University of Guelph, Guelph, N1G 2W1, Canada.

Published: January 2009

This article discusses the optimization of a newly developed method for measuring the activity of plasminogen activators using a thickness-shear-mode acoustic sensor. A variable-size simplex algorithm was used for optimization. Preliminary tests were performed to design the first simplex. A desirability function was defined to translate each performance value to a membership value of 0 to 1. If there was more than one performance variable, their membership values were translated to an aggregated membership value using another function that considers their individual influence on sensor performance. Two rounds of optimization were carried out for streptokinase followed by a single optimization for tissue-type plasminogen activator. In the last optimization, ratios of control variables were used in order to reduce the number of parameters and to formulate easily adjustable assay conditions. The results showed the usefulness of the simplex method for optimizing this type of assay, and the importance of preliminary tests and prior knowledge in providing rapid convergence using fewer experiments. The optimized plasminogen activator assay can be considered a reference method for measurement of all members of this drug class.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-008-2483-0DOI Listing

Publication Analysis

Top Keywords

plasminogen activators
8
preliminary tests
8
plasminogen activator
8
optimization
5
simplex
4
simplex optimization
4
optimization acoustic
4
assay
4
acoustic assay
4
plasminogen
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!