A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quantification of organophosphorus nerve agent metabolites using a reduced-volume, high-throughput sample processing format and liquid chromatography-tandem mass spectrometry. | LitMetric

Quantification of organophosphorus nerve agent metabolites using a reduced-volume, high-throughput sample processing format and liquid chromatography-tandem mass spectrometry.

J Anal Toxicol

Centers for Disease Control and Prevention, National Center for Environmental Health, Division of Laboratory Sciences, Emergency Response and Air Toxicants Branch, 4770 Buford Highway, MS F44, Atlanta, Georgia 30341, USA.

Published: January 2009

A reduced-volume, high-throughput analytical method has been developed for the quantification of organophosphorus (OP) nerve agent metabolites in human urine. Metabolites of soman, sarin, cyclohexyl-sarin, VX, and Russian-VX were quantified down to a lowest reportable limit of 1 ng/mL in human urine. One hundred microliter urine samples were preconcentrated using normal-phase 96-well solid-phase extraction silica sorbent beds. Dual-column hydrophilic interaction liquid chromatography was applied in a 2.5-min isocratic separation followed by negative electrospray isotope-dilution multiple-reaction-monitoring mass spectrometry. Method validation included the characterization of two synthetic urine pools, relative recovery experiments, and calculation of the method limit of detection. All liquid handling steps were processed in a high-density 96-well format, including sample aliquoting, extraction, dry-down, and reconstitution. This allows up to 3840 unknown samples, plus calibrators and quality control materials, to be prepared on a single liquid handler in a 24-h period. In a public health emergency involving OP-nerve agents, this method provides the sample preparation and analytical capacity to respond rapidly to a large number of patient samples.

Download full-text PDF

Source
http://dx.doi.org/10.1093/jat/32.9.774DOI Listing

Publication Analysis

Top Keywords

quantification organophosphorus
8
organophosphorus nerve
8
nerve agent
8
agent metabolites
8
reduced-volume high-throughput
8
mass spectrometry
8
human urine
8
metabolites reduced-volume
4
high-throughput sample
4
sample processing
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!