A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development and validation of a liquid chromatography coupled with atmospheric-pressure chemical ionization ion trap mass spectrometric method for the simultaneous determination of triptolide, tripdiolide, and tripterine in human serum. | LitMetric

A sensitive method has been developed and validated for the simultaneous determination of triptolide, tripdiolide, and tripterine in human serum using hydrocortisone as an internal standard (IS). After triptolide, tripdiolide, and tripterine in human serum were extracted with ethyl acetate, the extracts were separated on an XDB C(18) column (30 mm x 2.1-mm i.d., 3 microm) using a mobile phase of acetic acid/ammonium acetate (5 mmol/L, pH 4.5)/acetonitrile/methanol in gradient elution. Detection was performed by high-performance liquid chromatography coupled with atmospheric-pressure chemical ionization ion trap mass spectrometry in negative multiple reaction monitoring mode. The transition ions m/z 359 --> 340, m/z 375 --> 357, m/z 449 --> 405, and m/z 419 --> 329 were selected for the quantification of triptolide, tripdiolide, tripterine, and IS, respectively. The linear range was 1.0-100.0 ng/mL, the absolute recoveries were between 78.3 and 89.2%, the relative recoveries were between 88.1 and 94.6%, and the limits of quantification in human serum were 0.5-1.0 ng/mL for the three target compounds. The intra- and interday relative standard deviations were less than 11.9% and 13.0%, respectively. This method was found to effectively and simultaneously determine trace triptolide, tripdiolide, and tripterine in human serum and can be suitable for clinical and toxicological studies.

Download full-text PDF

Source
http://dx.doi.org/10.1093/jat/32.9.737DOI Listing

Publication Analysis

Top Keywords

triptolide tripdiolide
20
tripdiolide tripterine
20
human serum
20
tripterine human
16
liquid chromatography
8
chromatography coupled
8
coupled atmospheric-pressure
8
atmospheric-pressure chemical
8
chemical ionization
8
ionization ion
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!