Multiparameter classifications of optical tomographic images.

J Biomed Opt

Columbia University, Department of Biomedical Engineering, New York, New York 10027, USA.

Published: February 2009

This research study explores the combined use of more than one parameter derived from optical tomographic images to increase diagnostic accuracy which is measured in terms of sensitivity and specificity. Parameters considered include, for example, smallest or largest absorption or scattering coefficients or the ratios thereof in an image region of interest. These parameters have been used individually in a previous study to determine if a finger joint is affected or not affected by rheumatoid arthritis. To combine these parameters in the analysis we employ here a vector quantization based classification method called Self-Organizing Mapping (SOM). This method allows producing multivariate ROC-curves from which sensitivity and specificities can be determined. We found that some parameter combinations can lead to higher sensitivities whereas others to higher specificities when compared to singleparameter classifications employed in previous studies. The best diagnostic accuracy, in terms of highest Youden index, was achieved by combining three absorption parameters [maximum(micro a), minimum(micro a), and the ratio of minimum(micro a) and maximum(micro a)], which result in a sensitivity of 0.78, a specificity of 0.76, a Youden index of 0.54, and an area under the curve (AUC) of 0.72. These values are higher than for previously reported single parameter classifications with a best sensitivity and specificity of 0.71, a Youden index of 0.41, and an AUC of 0.66.

Download full-text PDF

Source
http://dx.doi.org/10.1117/1.2981806DOI Listing

Publication Analysis

Top Keywords

optical tomographic
8
tomographic images
8
diagnostic accuracy
8
sensitivity specificity
8
multiparameter classifications
4
classifications optical
4
images study
4
study explores
4
explores combined
4
combined parameter
4

Similar Publications

Purpose: To determine whether corneal biomechanical parameters can predict ectasia progression.

Study Design: Retrospective observational study.

Methods: The baseline corneal biomechanical parameters of 64 eyes of 41 young patients (age, < 25 years at the first visit) who were diagnosed with keratoconus (KC) or suspected KC at Osaka University Hospital and followed up for more than two years were reviewed.

View Article and Find Full Text PDF

Keratoconus (KC) is a progressive corneal disorder resulting in severe visual impairment. We aimed to determine the prevalence and corneal tomographic characteristics of KC and keratoconus suspect (KCS) in a population-based study, and to construct discrimination models with or without corneal tomography. A total of 1,544 eyes (822 participants aged ≥35 years) were evaluated using data from the Yamagata Study (2015-2017).

View Article and Find Full Text PDF

This study assesses radiation doses in multi-slice computed tomography (CT) using epoxy resin and PMMA phantoms, focusing on the relationship between TAR (tissue air ratio) and kilovoltage peak (kVp). The research was conducted using a Hitachi Supria 16-slice CT scanner. An epoxy resin phantom was fabricated from commercially available materials, to simulate human tissue.

View Article and Find Full Text PDF

Purpose: To investigate different measures for corneal astigmatism in the context of reconstructed corneal astigmatism (recCP) as required to correct the pseudophakic eye, and to derive prediction models to map measured corneal astigmatism to recCP.

Methods: Retrospective single centre study of 509 eyes of 509 cataract patients with monofocal (MX60P) IOL. Corneal power measured with the IOLMaster 700 keratometry (IOLMK), and Galilei G4 keratometry (GK), total corneal power (TCP2), and Alpin's integrated front (CorT) and total corneal power (CorTTP).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!