Validation of A&D UA-85X device for blood pressure measurement.

Blood Press Monit

Department of Clinical and Experimental Medicine, University of Padova, Padua, Italy.

Published: December 2008

To determine the accuracy of the UA-85X (UA-851, 852, 853, 854, and 855) device developed by the A&D company. Device evaluations were performed using the protocol of the European Society of Hypertension (ESH). Monitor performance was assessed in relation to patients' age, arm circumference, and systolic and diastolic blood pressures (BPs). The device was assessed in two different samples according to ESH requirements, which are based on four zones of accuracy differing from the mercury standard by 5, 10, 15 mmHg, or more. The UA-85X passed all three phases of the protocol for systolic BP and diastolic BP. Mean BP difference between device and observers was -0.3+/-4.4 mmHg for systolic BP and -2.7+/-4.8 mmHg for diastolic BP. These passed the Association for the Advancement of Medical Instrumentation standard requirements. In multivariable analyses, systolic BP discrepancies between device and observers were related to age (P=0.03) and diastolic BP discrepancies were related to diastolic BP level (P<0.001). These data show that the UA-85X satisfies the recommended ESH and Advancement of Medical Instrumentation accuracy levels for both systolic BP and diastolic BP.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MBP.0b013e32830d4b77DOI Listing

Publication Analysis

Top Keywords

systolic diastolic
8
device observers
8
device
6
diastolic
5
validation a&d
4
a&d ua-85x
4
ua-85x device
4
device blood
4
blood pressure
4
pressure measurement
4

Similar Publications

Background: Maternal hemoglobin (Hb) is related to nutritional status, and it widely fluctuates during pregnancy. However, the relationship between Hb and blood pressure (BP) during pregnancy is unclear. This study aimed to estimate the associations between maternal Hb in various trimesters and its changes with BP during pregnancy.

View Article and Find Full Text PDF

Background: Plant-based foods have reduced protein digestibility and frequently display unbalanced amino acid profiles. Plant-based foods are therefore considered inferior to animal-based foods in their anabolic potential. No study has assessed the anabolic potential of a vegan diet that provides a large variety of plant-based protein sources in older adults.

View Article and Find Full Text PDF

Introduction: The aim of the observational SIMPLE study was to assess real-life effectiveness and safety of a single-pill combination (SPC) of perindopril arginine/amlodipine in a broad range of subjects with newly diagnosed mild-to-moderate hypertension treated in Canadian general practice.

Methods: Treatment-naïve participants aged 18-65 years with mild-to-moderate hypertension, whose physicians decided to initiate the perindopril/amlodipine SPC, were recruited from Canadian clinical practice from October 2017 to February 2019. Participants were followed at 3- (M3) and 6-month (M6) visits after treatment initiation.

View Article and Find Full Text PDF

Colonoscopy is a valuable tool for colorectal cancer screening and health checkups, with increasing utilization annually. Assisted entry is a standard procedure during electronic colonoscopy. In China, most clinically assisted colonoscopy procedures involve a nurse directly applying abdominal pressure to the patient's abdomen.

View Article and Find Full Text PDF

Aspirin may be necessary for some patients with cardiovascular disease, but previous studies on the use and dosage of aspirin and the association with hypertension have been inadequate. The results of existing studies have been somewhat inconsistent. Our study was designed to assess the association between prophylactic aspirin use and hypertension in U.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!