A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Diagnostic accuracy of the clock drawing test: the relevance of "time setting'' in screening for dementia. | LitMetric

Diagnostic accuracy of the clock drawing test: the relevance of "time setting'' in screening for dementia.

J Geriatr Psychiatry Neurol

Department of Psychiatry and Psychotherapy, Johann Wolfgang Goethe University, Heinrich-Hoffmann-Strasse 10, Frankfurt/Main, Germany.

Published: December 2008

Objective: We aimed to evaluate the overall diagnostic accuracy of clock drawing test methods which require a defined time setting. In addition, diagnostic relevance of time setting was analyzed qualitatively.

Methods: Clock drawing test performance of 462 consecutive memory clinic patients were analysed by 5 different clock drawing test methods. The sensitivity, specificity, positive and negative predictive value as well as the overall misclassification rate was calculated against a clinical diagnosis of dementia. Further, qualitative analysis of error types was done when subjects failed in the time setting task.

Results: All clock drawing test methods that require time setting revealed higher sensitivities and superior negative predictive values as well as overall misclassification rates compared to methods which do not. Failure in the time setting task did not exclusively occur in dementia patients. However, error types which reflect a severely reduced capacity in abstract and conceptual thinking occurred exclusively in dementia patients.

Discussion: Clock drawing test methods that require time setting should be favoured above methods which do not. An additional analysis of time setting errors may yield valuable diagnostic information.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0891988708324939DOI Listing

Publication Analysis

Top Keywords

time setting
28
clock drawing
24
drawing test
24
test methods
16
methods require
12
diagnostic accuracy
8
accuracy clock
8
negative predictive
8
well misclassification
8
error types
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!