Purpose: To find the factors which influence the acute increment of International Prostate Symptom Score (IPSS) after transperineal permanent interstitial implant (TPI) using (125)I seeds.

Patients And Methods: From April 2004 through September 2006, 104 patients with nonmetastatic prostate cancer underwent TPI without external-beam irradiation. Median patient age was 70 years with a median follow-up of 13.0 months. 73 patients (70%) received neoadjuvant hormone therapy. The increment of IPSS was defined as the difference between pre- and postimplant maximal IPSS. Clinical, treatment, and dosimetric parameters evaluated included age, initial prostate-specific antigen, Gleason Score, neoadjuvant hormone therapy, initial IPSS, post-TPI prostatic volume, number of implanted seeds, prostate V(100), V(150), D(90), urethral D(max), and urethral D(90). In order to further evaluate detailed urethral doses, the base and apical urethra were defined and the dosimetric parameters were calculated.

Results: The IPSS peaked 3 months after TPI and returned to baseline at 12-15 months. Multivariate analysis demonstrated a statistically significant correlation of post-TPI prostatic volume, number of implanted seeds, and the dosimetric parameters of the base urethra with IPSS increment.

Conclusion: The base urethra appears to be susceptible to radiation and the increased dose to this region deteriorates IPSS. It remains unclear whether the base urethral dose relates to the incidence of late urinary morbidities.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00066-008-1833-3DOI Listing

Publication Analysis

Top Keywords

dosimetric parameters
12
urethral dose
8
increment international
8
international prostate
8
prostate symptom
8
symptom score
8
ipss
8
score ipss
8
ipss transperineal
8
transperineal permanent
8

Similar Publications

Dosimetric Planning Comparison for Left Ventricle Avoidance in Non-small Cell Lung Cancer Radiotherapy.

Cureus

December 2024

Physics and Engineering, London Regional Cancer Program, London, CAN.

Introduction: Radiation may unintentionally injure myocardial tissue, potentially leading to radiation-induced cardiac disease (RICD), with the net benefit of non-small cell lung cancer (NSCLC) radiotherapy (RT) due to the proximity of the lung and heart. RTOG-0617 showed a greater reduction in overall survival (OS) comparing higher doses to standard radiation doses in NSCLC RT. VHeart has been reported as an OS predictor in the first- and fifth-year follow-ups.

View Article and Find Full Text PDF

Purpose: The objective of this study was to explore the performance of a predictive model for swallowing-induced breakthrough pain established using a redefined delineation method based on the common occurrence sites of radiation-induced oral mucositis (RIOM) in locally advanced nasopharyngeal carcinoma (NPC).

Methods And Materials: A total of 208 patients with locally advanced NPC were included in the study cohort, and the test cohort consisted of 88 patients. The oral mucosa structure was contoured using oral cavity contour (OCC), mucosal surface contour (MSC), and oral-pharyngeal mucosa (OPM) methods, and relevant dosimetric parameters were collected.

View Article and Find Full Text PDF

Validity of one-time phantomless patient-specific quality assurance in proton therapy with regard to the reproducibility of beam delivery.

Med Phys

January 2025

OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany.

Background: Patient-specific quality assurance (PSQA) is a crucial yet resource-intensive task in proton therapy, requiring special equipment, expertise and additional beam time. Machine delivery log files contain information about energy, position and monitor units (MU) of all delivered spots, allowing a reconstruction of the applied dose. This raises the prospect of phantomless, log file-based QA (LFQA) as an automated replacement of current phantom-based solutions, provided that such an approach guarantees a comparable level of safety.

View Article and Find Full Text PDF

Dosimetric comparison of CyberKnife and conventional linac prostate SBRT plans: analysis of the PACE-B Study.

Int J Radiat Oncol Biol Phys

January 2025

The Royal Marsden NHS Foundation Trust, London SM2 5PT, UK; Radiotherapy and Imaging Division, Institute of Cancer Research, London SM2 5NG, UK.

Purpose: In the PACE-B study, a non-randomised comparison of toxicity outcomes between stereotactic body radiotherapy (SBRT) platforms revealed fewer urinary side-effects with CyberKnife (CK) compared to conventional linac (CL) SBRT. This analysis compares baseline characteristics and planning dosimetry between the CK-SBRT and CL-SBRT cohorts in PACE-B, aiming to provide insight into possible reasons for differing toxicity outcomes between the platforms.

Methods: Dosimetric parameters for the surrogate urethra (SU), contoured urethra, bladder, bladder trigone (BT), and rectum were extracted from available CT planning scans of PACE-B SBRT patients.

View Article and Find Full Text PDF

Background: Radiotherapy for thymoma is delivered post-operatively in selected cases. Given the particular location of the thymic bed and the excellent prognosis, late cardiac toxicities may be an issue. The purpose of this retrospective dosimetric study is to investigate whether intensity-modulated proton beam therapy (IMPT) compared to photon therapy could better spare cardiac substructures, given prespecified dose constraints.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!