Study Objectives: Previous studies have shown that CPAP has a substantial impact on daytime symptoms and quality of life (QOL). It remains unclear which outcome measures best identify real CPAP effects and carry independent information.
Methods: One hundred-two men with moderate-severe obstructive sleep apnea were randomized to either "real" or "sham" CPAP for one month. Outcome measures were subjective sleepiness (Epworth Sleepiness Scale [ESS]) and QOL measures includiig SF-36/SF-12 and Calgary Sleep Apnea Quality of Life Index (SAQLI). The bed partner's QOL and rating of patient's response to CPAP were assessed with the Dublin questionnaire. All data were standardized using effect sizes and expressed as real minus sham to remove the nonspecific effects of placebo.
Results: Real CPAP was superior to sham CPAP in almost all outcome measures. ESS, patient's component from Dublin, and social interactions from SAQLI showed the largest differences in effect sizes between real and sham (1.33, 0.98, and 0.92 respectively). ESS carried the highest predictive power of real CPAP response (P < 0.0001, r2 = 0.21). Question number 5 from Dublin (partner assessed patient's sleep quality) and question 6 from ESS (dozing while talking) were the best single item predictors of real CPAP response.
Conclusions: Real CPAP reduces subjective sleepiness and improves QOL of both patients and bed partners. ESS is the best score; question number 5 from Dublin and question number 6 from ESS are the best single item predictors of real CPAP response. This information should allow the selection of appropriate questions in clinical practice and research protocols.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2579969 | PMC |
http://dx.doi.org/10.1093/sleep/31.11.1551 | DOI Listing |
Diagnostics (Basel)
December 2024
Pediatric Clinic, Parma University Hospital, Department of Medicine and Surgery, University of Parma, 43126 Parma, Italy.
Neonatal respiratory distress syndrome (RDS) is a common and potentially life-threatening condition in preterm infants, primarily due to surfactant deficiency. Early and accurate diagnosis is critical to guide timely interventions such as surfactant administration and respiratory support. Traditionally, chest X-rays have been used for diagnosis, but lung ultrasound (LUS) has gained prominence due to its non-invasive, radiation-free, and bedside applicability.
View Article and Find Full Text PDFCureus
November 2024
Oncology, University of Maryland, Adelphi, USA.
The management of chronic diseases has been revolutionized by the advent of wearable health technology. These devices provide personalized and real-time health data to patients. The problem that this technology is most frequently used to address is obesity and its consequences, heart disease, and certain cancers.
View Article and Find Full Text PDFBiomedicines
November 2024
Geriatrics Division, University Hospital "R. Dulbecco", 88100 Catanzaro, Italy.
Background: Obstructive sleep apnoea syndrome (OSAS) is an independent risk factor for cardiovascular morbidity and mortality and has a detrimental effect on vascular function, in particular on arterial stiffness and endothelial function. Continuous positive airway pressure (CPAP) is the gold-standard therapy for OSAS and its effects on arterial stiffness and endothelial function have been demonstrated in non-elderly patients.
Objectives: The objective of this study was to evaluate the effect of one year of CPAP treatment on arterial stiffness, through assessment of carotid-femoral pulse wave velocity (cf-PWV), and on endothelial function, through the reactive hyperaemia index (RHi), in a real-life cohort of elderly patients with moderate-to-severe OSAS and several comorbidities.
Eur Respir J
January 2025
Department of Cardiovascular, Neural and Metabolic Sciences, Istituto Auxologico Italiano IRCCS, Milan, Italy.
Background: Obstructive sleep apnoea (OSA) is associated with hypertension, and OSA treatment can reduce systolic blood pressure (SBP) and diastolic blood pressure (DBP), but with a modest mean effect size and vast heterogeneity among studies. The aim of this individual patient data (IPD) meta-analysis was to understand which OSA phenotypes could benefit the most in terms of BP reduction.
Methods: A systematic review of randomised controlled trials that compared continuous positive airway pressure (CPAP) with either passive or active treatment was conducted.
Sleep Med
December 2024
Center for Sleep and Wake Disorders, Institute of Medicine, Sahlgrenska Academy, Gothenburg University, Gothenburg, Sweden; Pulmonary Medicine, Sahlgrenska University Hospital, Gothenburg, Sweden. Electronic address:
Introduction: The Swedish Sleep Apnea Registry (SESAR) collects clinical data from individual obstructive sleep apnea (OSA) patients since 2010. SESAR has recently been integrated with additional national healthcare data. The current analysis presents the SESAR structure and representative clinical data of a national sleep apnea cohort.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!