Distal tibia nonunions.

Foot Ankle Clin

Department of Orthopaedic Surgery and Rehabilitation, University of Nebraska Medical Center, 981080 Nebraska Medical Center, Omaha, NE 68198-1080, USA.

Published: December 2008

Although tibia metaphyseal nonunion is rare, its treatment is often complex. The merits of related management techniques are discussed. These techniques include: intramedullary nailing, fine wire fixation, and blade plate reconstruction, which is the method preferred by the authors.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.fcl.2008.09.001DOI Listing

Publication Analysis

Top Keywords

distal tibia
4
tibia nonunions
4
nonunions tibia
4
tibia metaphyseal
4
metaphyseal nonunion
4
nonunion rare
4
rare treatment
4
treatment complex
4
complex merits
4
merits management
4

Similar Publications

Gait Analysis in Patients After Hemiepiphysiodesis Due to Valgus or Varus Knee Deformity.

J Clin Med

January 2025

Department of Orthopaedic and Trauma Surgery, Institute of Medical Sciences, University of Opole, 45-040 Opole, Poland.

Developmental knee joint deformities are a common problem in pediatric orthopedics. Children with a valgus or varus deformity of the distal femur or the proximal tibia are commonly treated with hemiepiphysiodesis. Gait analysis in patients with lower limb deformities plays an important role in clinical practice.

View Article and Find Full Text PDF

Clinical Efficacy of Three-Dimensional-Printed Pure Titanium Fracture Plates with Locking Screw Systems in Distal Tibia Fractures.

Medicina (Kaunas)

January 2025

Department of Orthopedic Surgery, Anam Hospital, Korea University College of Medicine, 73 Goryeodae-ro Seongbuk-gu, Seoul 02841, Republic of Korea.

Distal tibia fractures are high-energy injuries characterized by a mismatch between standard plate designs and the patient's specific anatomical bone structure, which can lead to severe soft tissue damage. Recent advancements have focused on the development of customized metal plates using three-dimensional (3D) printing technology. However, 3D-printed metal plates using titanium alloys have not incorporated a locking system due to the brittleness of these alloys.

View Article and Find Full Text PDF

The paper presents a detailed gross anatomical description of the elements of the pelvic limb in the African green monkey and provides comparative and differential elements on pelvic limb monkey osteology. The osteometric investigation adds value to the gross morphological and radiological investigation, adjoining metric data to the gross descriptive data set. The main methodology used was the gross morphological investigation, doubled by regular osteometrical and radiographical assessments.

View Article and Find Full Text PDF

Background/objectives: Salter-Harris II (SH-II) distal tibia fractures are the most common physeal ankle fractures in children; however, indications for surgical management remain controversial, and patient-reported outcomes for different management strategies are unknown. The purpose of the current study is to compare differences in clinical and patient-reported outcomes following operative and non-operative management of this injury.

Methods: We performed a retrospective cohort study of pediatric patients who were treated at a single institution for SH-II distal tibia fractures between 2013 and 2020.

View Article and Find Full Text PDF

Background: Chondroblastoma is classified as a benign bone tumor. However, postoperative local recurrence remains a concern. We analyzed the factors contributing to chondroblastoma local recurrence and the clinical challenges associated with treating these patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!