Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A sensitive and rapid liquid chromatography-mass spectrometric method for the determination of ophiopogonin D in rat plasma was developed and validated. Chromatographic separation was performed on a C (18) column using a step gradient program with the mobile phase of 0.5 mmol/L ammonium chloride solution and acetonitrile. Ophiopogonin D was quantified using an electrospray negative ionization mass spectrometry in the selected ion monitoring (SIM) mode using digoxin as an internal standard. Good linearity was obtained in the concentration range of 2.5 - 480.0 ng/mL ( R2 = 0.9984). The lower limit of quantification (LLOQ) and lower limit of detection (LLOD) were 2.5 ng/mL and 1.0 ng/mL, respectively. Both the intra- and inter-day precision was less than 8.9 % and the accuracy was within 97.5 - 107.3 %. The pharmacokinetic study of ophiopogonin D in rats was then defined using the method after intravenous dosing (77.0 microg/kg). The plasma concentration-time profile for ophiopogonin D was best fitted to an open two-compartment model with a clearance of 0.024 +/- 0.010 L/min/kg and a terminal half life of 17.29 +/- 1.70 min. A comparison of the pharmacokinetics of ophiopogonin D as a pure compound and as a component of 'SHENMAI' injection revealed a significantly smaller clearance of ophiopogonin D (0.007 +/- 0.002 L/min/kg) for the latter formulation, consistent with an inhibition by one or more other components in the formulation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1055/s-0028-1088339 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!