A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Enantiomeric separation of Linezolid by chiral reversed-phase liquid chromatography. | LitMetric

Enantiomeric separation of Linezolid by chiral reversed-phase liquid chromatography.

J Chromatogr Sci

Suven Life Sciences Limited, Serene Chambers, Road # 5, Avenue 7, Banjara Hills, Hyderabad - 500034, India.

Published: October 2008

A chiral liquid chromatographic method is developed for the enantiomeric resolution of Linezolid, (S)(-)-N-[[-3-(3-fluoro-4-(4-morpholinyl)phenyl]-2-oxo-5-oxazolidinyl] methyl] acetamide, an antibiotic in bulk drugs. The enantiomers of Linezolid are resolved on a Chiralcel OJ-RH column using a mobile phase system containing 150mM di-sodium hydrogen phosphate buffer (pH 4.5)-acetonitrile (86:14, v/v). The resolution between the enantiomers is found to be two. The developed method is extensively validated and proved to be robust. The limit of detection and limit of quantification of (R)-enantiomers are found to be 94 and 375 ng/mL, respectively, for 10 microL injection volume. The percentage recovery of (R)-enantiomer is ranged from 98.9 to 102.9 in bulk drug samples of Linezolid. Linezolid sample solution and mobile phase are found to be stable for at least 48 h. The proposed method is found to be suitable and accurate for the quantitative determination of (R)-enantiomer in bulk drugs.

Download full-text PDF

Source
http://dx.doi.org/10.1093/chromsci/46.9.764DOI Listing

Publication Analysis

Top Keywords

bulk drugs
8
mobile phase
8
linezolid
5
enantiomeric separation
4
separation linezolid
4
linezolid chiral
4
chiral reversed-phase
4
reversed-phase liquid
4
liquid chromatography
4
chromatography chiral
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!