Polypropylene suture-guided valve tube for posterior chamber implantation in patients with pseudophakic glaucoma.

J Cataract Refract Surg

Department of Ophthalmology, Clinica Universitaria de Navarra, Facultad de Medicina, Universidad de Navarra, Pamplona, Spain.

Published: November 2008

We describe a new surgical procedure for implanting a glaucoma drainage tube in the posterior chamber. A needle with a 10-0 polypropylene suture is introduced into the posterior chamber, and a 23-gauge needle is also introduced as the barrel on the polypropylene needle tip. After the 23-gauge needle is withdrawn from the posterior chamber, the polypropylene needle tip is pulled and the suture crosses the anterior and posterior chambers. A sliding knot is made around the drainage tube. The tube is pushed into the scleral tunnel and posterior chamber as the suture is pulled to position the tube. The knot is loosened and the suture removed from the eye by pulling from either side. This procedure is easy and effective for implanting a tube in the posterior chamber in pseudophakic eyes and is indicated after penetrating keratoplasty or in eyes with compromised endothelial function.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcrs.2008.05.063DOI Listing

Publication Analysis

Top Keywords

posterior chamber
24
tube posterior
12
drainage tube
8
23-gauge needle
8
polypropylene needle
8
posterior
7
tube
6
chamber
6
needle
5
polypropylene
4

Similar Publications

Purpose: To evaluate the accuracy of toric intraocular lens (IOL) axis prediction between two preoperative measurement devices: the optical biometry (IOLMaster 500 or 700) and the dual Scheimpflug topography (Galilei G4).

Methods: Medical records of 64 eyes from 44 patients who underwent phacoemulsification and posterior chamber toric IOL (Zeiss AT TORBI 709M) implantation between July 2017 and January 2022 were reviewed. All patients underwent preoperative evaluation by optical biometry (IOLMaster 500 or IOLMaster 700) and Galilei G4.

View Article and Find Full Text PDF

Purpose: Aqueous humor inflow rate, a key parameter influencing aqueous humor dynamics, is typically measured by fluorophotometry. Analyzing fluorophotometric data depends, inter alia, on the volume of aqueous humor in the anterior chamber but not the posterior chamber. Previous fluorophotometric studies of the aqueous inflow rate in mice have assumed the ratio of anterior:posterior volumes in mice to be similar to those in humans.

View Article and Find Full Text PDF

Background: To evaluate the biosafety, reduction in anterior capsule opacification, and fluctuation in intraocular pressure (IOP) of a new phakic refractive lens (PRL) with a sinusoidal drainage groove design.

Methods: This self-controlled experiment was performed on eight eyes of four rabbits. Each rabbit was implanted with a sinusoidal PRL (PRL-S5) in the right eye and a conventional posterior chamber PRL (PC-PRL) in the left eye.

View Article and Find Full Text PDF

Comparison of the Efficacy of Endoscopic Continuous Perfusion Combined With Y-Shaped Incision and Microscopic Retroauricular Incision in the Treatment of Attic Cholesteatoma: A Randomized Prospective Study.

Ear Nose Throat J

January 2025

Department of Otolaryngology, Northern Jiangsu People's Hospital, Institute of Translational Medicine, Medical College, Yangzhou University, Yangzhou, PR China.

This study aimed to compare the efficacy of continuous perfusion of underwater bone grinding combined with a -shaped incision versus a microscopic posterior ear incision in the treatment of attic cholesteatoma. Clinical trials were prospective studies from the Northern Jiangsu People's Hospital. Adult patients with middle ear cholesteatoma requiring ear surgery agreed to participate between September 2019 and September 2023 (age > 18).

View Article and Find Full Text PDF

Over the past two decades, both suture and sutureless techniques for scleral fixation of intraocular lenses have seen significant advancement, driven by improvements in methodologies and instrumentation. Despite numerous reports demonstrating the effectiveness, safety, and superiority of these techniques, each approach carries with it its own drawbacks, including an elevated risk of certain postoperative complications. This article delves into various surgical techniques for scleral fixation of posterior chamber intraocular lenses, discussing their procedural nuances, benefits, drawbacks, postoperative complications, and outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!