The bilateral filter is a nonlinear filter that does spatial averaging without smoothing edges; it has shown to be an effective image denoising technique. An important issue with the application of the bilateral filter is the selection of the filter parameters, which affect the results significantly. There are two main contributions of this paper. The first contribution is an empirical study of the optimal bilateral filter parameter selection in image denoising applications. The second contribution is an extension of the bilateral filter: multiresolution bilateral filter, where bilateral filtering is applied to the approximation (low-frequency) subbands of a signal decomposed using a wavelet filter bank. The multiresolution bilateral filter is combined with wavelet thresholding to form a new image denoising framework, which turns out to be very effective in eliminating noise in real noisy images. Experimental results with both simulated and real data are provided.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2614560 | PMC |
http://dx.doi.org/10.1109/TIP.2008.2006658 | DOI Listing |
J Vasc Surg Cases Innov Tech
April 2025
Department of Cardiovascular Surgery, Higashiosaka City Medical Center, Higashiosaka, Osaka, Japan.
A 69-year-old man with chest pain was diagnosed with acute type B aortic dissection with the entry tear located at distal arch and a distal aortic arch aneurysm. Therefore, we performed debranching thoracic endovascular aortic repair 2 weeks after type B aortic dissection onset. First, the graft was anastomosed to bilateral axillary arteries.
View Article and Find Full Text PDFBMJ Case Rep
January 2025
Northern Genetics Service, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK.
Paired box 2 ()-related disorder, also known as renal coloboma syndrome, is a variably penetrant autosomal dominant condition, associated with renal and ophthalmological abnormalities. We report a child with -related disorder who presented atypically with acute ataxia on a background of stage 3 chronic kidney disease. Extensive biochemical, radiological and gene agnostic rapid trio exome sequencing was non-diagnostic.
View Article and Find Full Text PDFPhys Med
January 2025
Department of Robotics and Mechatronics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), 333 Techno Jungang-daero, Hyeonpung-eup, Dalseong-gun, Daegu, 42988, Republic of Korea. Electronic address:
Purpose: Material decomposition induces substantial noise in basis images and their synthesized computed tomography (CT) images. A likelihood-based bilateral filter was previously developed as a neighborhood filter that effectively reduces noise. However, this method is sensitive to image contrast, and the noise texture needs improvement.
View Article and Find Full Text PDFDiagnostics (Basel)
December 2024
Postgraduation School in Radiodiagnostics, Università degli Studi di Milano, Via Festa del Perdono 7, 20122 Milan, Italy.
Dynamic digital radiography (DDR) is a recent imaging technique that allows for real-time visualization of thoracic and pulmonary movement in synchronization with the breathing cycle, providing useful clinical information. A 46-year-old male, a former smoker, was evaluated for unexplained dyspnea and reduced exercise tolerance. His medical history included a SARS-CoV-2 infection in 2021.
View Article and Find Full Text PDFJ Speech Lang Hear Res
January 2025
Department of Communication Sciences and Disorders, Baylor University, Waco, TX.
Purpose: The aim of this study was to measure the effects of frequency spacing (i.e., F2 minus F1) on spectral integration for vowel perception in simulated bilateral electric-acoustic stimulation (BiEAS), electric-acoustic stimulation (EAS), and bimodal hearing.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!