We report a measurement of the exclusive e+ e- -->Lambda+_(c)Lambda-_(c) cross section as a function of center-of-mass energy near the Lambda+_(c)Lambda-_(c) threshold. A clear peak with a significance of 8.2sigma is observed in the Lambda+_(c)Lambda-_(c) invariant mass distribution just above threshold. With an assumption of a resonance origin for the observed peak, a mass and width of M=[4634 (+8)_(-7)(stat)(+5)_(-8)(syst)] MeV/c(2) and Gamma_(tot)=[92 (+40)_(-24)(stat)(+10)_(-21)(syst)] MeV are determined. The analysis is based on a study of events with initial-state-radiation photons in a data sample collected with the Belle detector at the Upsilon(4S) resonance and nearby continuum with an integrated luminosity of 695 fb(-1) at the KEKB asymmetric-energy e+ e- collider.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1103/PhysRevLett.101.172001 | DOI Listing |
We report a measurement of the exclusive e+ e- -->Lambda+_(c)Lambda-_(c) cross section as a function of center-of-mass energy near the Lambda+_(c)Lambda-_(c) threshold. A clear peak with a significance of 8.2sigma is observed in the Lambda+_(c)Lambda-_(c) invariant mass distribution just above threshold.
View Article and Find Full Text PDFAppl Opt
September 1997
Department of Physics, University of Minnesota Duluth, Duluth, Minnesota 55812, USA.
We use remote sensing reflectance (RSR) together with the inherent optical properties of suspended particulates to determine the backscattering ratio b(b)/b for coastal waters. We examine the wavelength dependence of b(b)(lambda) and f(lambda)/Q(lambda) and establish the conditions when C(lambda) in RSR(lambda) approximately or = C(lambda)b(b)(lambda)/a(lambda) can be treated as a constant. We found that for case 2 waters, RSR was insensitive to the natural fluctuations in particle-size distributions.
View Article and Find Full Text PDFJ Chem Phys
November 2004
Department of Physics, Tokyo Metropolitan University, Minami-Ohsawa, Hachioji, Tokyo 192-0397, Japan.
The deexcitation process of an atom in an optically allowed excited state by a collision with an axially symmetric molecule is considered. In order to make a precise comparison with experimental data that have recently been obtained, we extend previous work for a Penning ionization process [T. Watanabe and K.
View Article and Find Full Text PDFThe Japan Society of Medical Physics (JSMP) has published a new dosimetry protocol "JSMP-01" (standard dosimetry of absorbed dose in external beam radiotherapy) which conforms to the recommendations of the International Atomic Energy Agency (IAEA TRS-398) and the American Association of Physicists in Medicine (AAPM TG-51) protocols for the calibration of radiotherapy beams. Since the new protocol offers the physical data for the Famer-type ionization chambers of the various wall materials, the user can measure the absorbed dose at reference point (D(r)) using most of the commercially available Famer-type ionization chambers. In this paper, the six Famer-type ionization chambers of the various wall materials are examined for photon beam by two ways.
View Article and Find Full Text PDFJ Immunol
July 2002
Department of Immunology, Erasmus University Rotterdam/University Hospital Rotterdam, Rotterdam, The Netherlands.
Two polymorphisms of the human Ig(lambda) (IGL) locus have been described. The first polymorphism concerns a single, 2- or 3-fold amplification of 5.4 kb of DNA in the C(lambda)2-C(lambda)3 region.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!