AI Article Synopsis

  • The study measures the CP asymmetry in the decay of B mesons to better understand their behavior, using data from 383 million B[over] B events collected by the BABAR detector.
  • They focused on reconstructing 16 specific decay modes that involve a high-energy photon and a certain s quark-containing hadronic system.
  • The CP asymmetry was found to be -0.011, with a statistical uncertainty of ±0.030 and a systematic uncertainty of ±0.014, for hadronic system masses between 0.6 and 2.8 GeV/c².

Article Abstract

We perform a measurement of the CP asymmetry in b-->sgamma decays using a sample of 383 x 10(6) B[over] B events collected by the BABAR detector at the SLAC PEP-II asymmetric B factory. We reconstruct 16 flavor-specific B decay modes containing a high-energy photon and a hadronic system X_(s) containing an s quark. We measure the CP asymmetry to be -0.011+/-0.030(stat)+/-0.014(syst) for a hadronic system mass between 0.6 and 2.8 GeV/c(2).

Download full-text PDF

Source
http://dx.doi.org/10.1103/PhysRevLett.101.171804DOI Listing

Publication Analysis

Top Keywords

measurement asymmetry
8
asymmetry b-->sgamma
8
hadronic system
8
b-->sgamma sum
4
sum exclusive
4
exclusive final
4
final states
4
states perform
4
perform measurement
4
b-->sgamma decays
4

Similar Publications

Objectives: To evaluate whether unilateral functional posterior crossbite in growing children creates an asymmetry in masseter muscle thickness and whether this asymmetry is normalized after crossbite correction.

Materials And Methods: Two groups of growing individuals were studied prospectively: (i) a treatment group: children with unilateral functional posterior crossbite, undergoing crossbite correction with maxillary expansion; and (ii) a control group: children without transversal malocclusions and orthodontic treatment. The thickness of the masseter muscles was measured bilaterally using ultrasonographic recordings at three time points: pre-treatment (T0); 9 months after (T1); and 30 months after posterior crossbite correction (T2); and at equivalent time points in the control group.

View Article and Find Full Text PDF

Canine hip dysplasia (CHD) screening relies on accurate positioning in the ventrodorsal hip extended (VDHE) view, as even mild pelvic rotation can affect CHD scoring and impact breeding decisions. This study aimed to assess the association between pelvic rotation and asymmetry in obturator foramina areas (AOFAs) and to develop a computer vision model for automated AOFA measurement. In the first part, 203 radiographs were analyzed to examine the relationship between pelvic rotation, assessed through asymmetry in iliac wing and obturator foramina widths (AOFWs), and AOFAs.

View Article and Find Full Text PDF

Given the increasing use of innovative force plate systems in applied sports settings and the impact that anterior cruciate ligament (ACL) injuries have on team success, the purpose of the present study was to compare the lower-body neuromuscular performance characteristics of athletes who underwent ACL reconstruction (ACLR) and their non-injured counterparts (i.e., healthy controls).

View Article and Find Full Text PDF

Effect of Monosaccharides Including Rare Sugars on the Bilayer Phase Behavior of Dimyristoylphosphatidylcholine.

Membranes (Basel)

December 2024

Department of Bioengineering, Division of Bioscience and Bioindustry, Graduate School of Technology, Industrial and Social Sciences, Tokushima University, 2-1 Minamijosanjima-cho, Tokushima 770-8513, Japan.

We observed bilayer phase transitions of dimyristoylphosphatidylcholine (DMPC) in aqueous solutions of four kinds of monosaccharides, namely, D-glucose, D-fructose, D-allose and D-psicose, using differential scanning calorimetry (DSC). D-allose (C3-epimer of D-glucose) and D-psicose (C3-epimer of D-fructose) are rare sugars. We performed DSC measurements using two types of sugar-containing sample dispersions of the DMPC vesicles: one is a normal sample dispersion with no concentration asymmetry between the inside and outside of the vesicles and the other is an unusual sample dispersion with a concentration asymmetry.

View Article and Find Full Text PDF

Intra and Inter-Test Reliability of Isometric Hip Adduction Strength Test with Force Plates in Professional Soccer Players.

J Funct Morphol Kinesiol

December 2024

Escuela de Ciencias de la Actividad Física, El Deporte y la Salud, Facultad de Ciencias Médicas, Universidad de Santiago de Chile, Santiago 8370003, Chile.

Assessing the reliability of measurement instruments and equipment is essential to ensure the accurate tracking of athletes over extended periods, minimizing the measurement errors caused by chance or other factors. However, a less common but equally important analysis is the verification of inter-measurement agreement, which complements the reliability results. To evaluate the intra- and inter-test reliability of an isometric hip adduction strength and asymmetries test in professional soccer players.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!