Acute rejection (AR) remains a significant complication in renal transplant patients. Using serum creatinine for AR screening has proven problematic, and thus a noninvasive, highly sensitive and specific test is needed. T cells from human peripheral blood were analyzed using Raman spectroscopy. Fifty-one Mixed Lymphocyte Culture (MLC) activated T cells (ATC), 28 Mitomycin C inactivated T cells (ITC), and 35 resting T cells (RTC), were studied utilizing 785 and 514.5 nm wavelengths. Statistical analysis following subtraction of fluorescence used Student's t test to quantify peak ratio differences and discriminant function analysis (DFA), with three distinct sectors assigned for grouping purposes: Sector I, ITC; Sector II, ATC; Sector III, RTC. Differences between ATC and non-activated T cells (ITC and RTC) were found at 1182 and 1195 cm-1 peak positions for both wavelengths. Significant differences in peak ratios for 785 and 514.5 nm wavelengths existed between ATC and RTC (p=0.001 and p=0.006, respectively) and ATC and ITC (p=0.001 and p=0.001, respectively), with a trend in differences observed between ITC and RTC (p=0.07 and p=0.08, respectively). Analysis of the DFA-derived sector distribution for the 785 and 514.5 nm wavelengths revealed a sensitivity of 95.7% and 89.3%, respectively, and a specificity of 100% and 93.8%, respectively. This data suggests that Raman spectroscopy can detect significant differences between activated and nonactivated T cells based upon cell-surface receptor expression, thereby establishing unique signatures that can aid in the development of a noninvasive AR screening tool with high sensitivity and specificity.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2718683PMC
http://dx.doi.org/10.1016/j.jim.2008.10.001DOI Listing

Publication Analysis

Top Keywords

785 5145
12
5145 wavelengths
12
raman spectroscopy
8
cells itc
8
itc rtc
8
cells
6
atc
5
itc
5
rtc
5
differences
5

Similar Publications

To evaluate the "resting" pH and induced pH changes in denture plaque, soft deposits were collected from the fitting surface of the denture, pooled and suspended in water. Plaque pH was determined with microelectrode equipment before and after mouth rinsing with a sucrose solution. A characteristic level in the "resting" pH of denture plaque was found in most of 12 subjects tested.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!