A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Manikins with human-like chest properties--a new tool for chest compression research. | LitMetric

Manikins with human-like chest properties--a new tool for chest compression research.

IEEE Trans Biomed Eng

Laerdal Medical, 4002 Stavanger, Norway.

Published: November 2008

AI Article Synopsis

  • Commercial CPR training manikins don't accurately replicate the mechanical properties of real human chests, which could hinder CPR research.
  • The study involves measuring the chest stiffness and damping of 59 cardiac arrest patients during CPR to develop more realistic training manikins.
  • A new manikin was created with eight interchangeable force-depth profiles that closely match the mechanical properties of actual patients' chests, validated by matching measurements within a specified range.

Article Abstract

Commercially available training manikins for cardiopulmonary resuscitation (CPR) do not accurately mimic the mechanical properties of human chests. This may limit the usefulness of CPR research performed on such manikins. This paper presents the construction of manikins with chest properties matching those measured in patients during an ongoing CPR. The chest stiffness and damping of 59 cardiac arrest patients was measured during out-of-hospital CPR, using a defibrillator with a compression sensor with built-in force sensor and accelerometer. A manikin with eight interchangeable chest force-depth profiles, representing the measured range of chest stiffness and the average damping of these patients, was then specified and constructed. The stiffness and damping of the manikins were verified using the same equipment and method as was used during data collection. Between 30 and 50 mm compression depth, the force-depth relationship of all eight manikins were found to be within +/-30 N of force or +/-2 mm of depth from the reference specifications derived from measurements on patients' chests. The average damping was also found to closely match the specified value.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBME.2008.2001289DOI Listing

Publication Analysis

Top Keywords

chest stiffness
8
stiffness damping
8
average damping
8
manikins
6
chest
6
manikins human-like
4
human-like chest
4
chest properties--a
4
properties--a tool
4
tool chest
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!