High frame-rate ultrasound RF data acquisition has been proved to be critical for novel cardiovascular imaging techniques, such as high-precision myocardial elastography, pulse wave imaging (PWI), and electromechanical wave imaging (EWI). To overcome the frame-rate limitations on standard clinical ultrasound systems, we developed an automated method for multi-sector ultrasound imaging through retrospective electrocardiogram (ECG) gating on a clinically used open architecture system. The method achieved both high spatial (64 beam density) and high temporal resolution (frame rate of 481 Hz) at an imaging depth up to 11 cm and a 100% field of view in a single breath-hold duration. Full-view imaging of the left ventricle and the abdominal aorta of healthy human subjects was performed using the proposed technique in vivo. ECG and ultrasound RF signals were simultaneously acquired on a personal computer (PC). Composite, full-view frames both in RF- and B-mode were reconstructed through retrospective combination of seven small (20%) juxtaposed sectors using an ECG-gating technique. The axial displacement of the left ventricle, in both long-axis and short-axis views, and that of the abdominal aorta, in a long-axis view, were estimated using a RF-based speckle tracking technique. The electromechanical wave and the pulse wave propagation were imaged in a ciné-loop using the proposed imaging technique. Abnormal patterns of such wave propagation can serve as indicators of early cardiovascular disease. This clinical system could thus expand the range of applications in cardiovascular elasticity imaging for quantitative, noninvasive diagnosis of myocardial ischemia or infarction, arrhythmia, abdominal aortic aneurysms, and early-stage atherosclerosis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TUFFC.921 | DOI Listing |
J Feline Med Surg
January 2025
College of Veterinary Medicine, China Agricultural University, Beijing, China.
Objectives: This study aimed to assess left atrial (LA) size in healthy cats using cardiovascular MRI (cMRI) and to compare this with LA size assessed by two-dimensional echocardiography. The hypothesis was that cMRI would accurately determine LA size in domestic cats.
Methods: A prospective comparative study was performed.
J Neuroinflammation
January 2025
Department of Medical and Translational Biology, Umeå university, Umeå, 901 87, Sweden.
Background: Normal brain aging is associated with dopamine decline, which has been linked to age-related cognitive decline. Factors underlying individual differences in dopamine integrity at older ages remain, however, unclear. Here we aimed at investigating: (i) whether inflammation is associated with levels and 5-year changes of in vivo dopamine D2-receptor (DRD2) availability, (ii) if DRD2-inflammation associations differ between men and women, and (iii) whether inflammation and cerebral small-vessel disease (white-matter lesions) serve as two independent predictors of DRD2 availability.
View Article and Find Full Text PDFCancer Imaging
January 2025
Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China.
Background: Previous studies utilizing dual-energy CT (DECT) for evaluating treatment efficacy in nasopharyngeal cancinoma (NPC) are limited. This study aimed to investigate whether the parameters from DECT can predict the response to induction chemotherapy in NPC patients in two centers.
Methods: This two-center retrospective study included patients diagnosed with NPC who underwent contrast-enhanced DECT between March 2019 and November 2023.
J Transl Med
January 2025
Guangdong Provincial Key Laboratory of Artificial Intelligence in Medical Image Analysis and Application, Guangdong Provincial People's Hospital, Guangzhou, China.
Fluids Barriers CNS
January 2025
Laboratory for Therapeutic and Diagnostic Antibodies, KU Leuven - University of Leuven, O&N II Herestraat 49 box 820, 3000, Leuven, Belgium.
Background: Therapeutic antibodies for the treatment of neurological disease show great potential, but their applications are rather limited due to limited brain exposure. The most well-studied approach to enhance brain influx of protein therapeutics, is receptor-mediated transcytosis (RMT) by targeting nutrient receptors to shuttle protein therapeutics over the blood-brain barrier (BBB) along with their endogenous cargos. While higher brain exposure is achieved with RMT, the timeframe is short due to rather fast brain clearance.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!