There is no gold standard for the measurement of pulmonary regurgitation (PR) severity. Two-dimensional (2D) transthoracic echocardiography is most commonly used to quantify PR severity using color Doppler criteria for aortic regurgitation. However, this method is limited by visualization of only one or two dimensions of the proximal PR jet or vena contracta (VC) precluding accurate assessment of its shape or size. This limitation would be expected to be obviated by three-dimensional (3D) transthoracic echocardiography, which could provide a more accurate quantitative assessment of PR severity. This study evaluated 82 adult patients with PR using 2D and 3D. PR VC area by 3D was obtained by planimetry by positioning the cropping plane exactly parallel to the VC, which was viewed en face by cropping of the 3D data set. Regurgitant volumes were calculated by 2D (assuming a circular VC) and by 3D as a product of the VC and velocity time integral obtained by color Doppler-guided conventional Doppler interrogation of the PR jet.The 3D VC area correlated with 2D jet width (JW)/right ventricular outflow tract (RVOT) width (r = 0.71) and 2D VC area (r = 0.79). 3D JW/RVOT width correlated with 2D JW/RVOT (r = 0.87). 3D regurgitant volumes also correlated with 2D regurgitant volumes (r = 0.76). The 3D VC values of <0.20, 0.20-0.45, 0.46-1.15, and >1.15 cm(2) and regurgitant volumes of <15 ml, 15-50 ml, 51-115 ml, and >115 ml were effective as cutoffs for grades 1, 2, 3, and 4 PR, respectively. In conclusion, quantification of 3D VC area and regurgitant volumes correlate reasonably well with the current 2D methods for measurement of PR. Since 3D visualizes PR VC in three dimensions, it would be expected to provide a more accurate and more quantitative assessment of PR severity as compared to 2D.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8175.2008.00721.xDOI Listing

Publication Analysis

Top Keywords

regurgitant volumes
20
three-dimensional transthoracic
8
pulmonary regurgitation
8
transthoracic echocardiography
8
provide accurate
8
accurate quantitative
8
quantitative assessment
8
assessment severity
8
regurgitant
5
volumes
5

Similar Publications

Background: Stroke volume index (SVI) is an important prognostic parameter in pulmonary arterial hypertension (PAH). The direct Fick (DF) method represents the gold standard for measuring it. Indirect Fick (IF) and thermodilution (TD) are simpler and widely used alternatives.

View Article and Find Full Text PDF

: Transcatheter aortic valve implantation (TAVI) has emerged as a pivotal intervention for managing severe aortic stenosis in high-risk surgical patients. : This study aimed to evaluate the impacts of procedural factors and patient characteristics on TAVI outcomes, with a focus on survival rates, cardiac mortality, and associated complications. : A retrospective, single-center study involving 224 patients who underwent TAVI at the Lithuanian University of Health Sciences from September 2021 to April 2023 was conducted.

View Article and Find Full Text PDF

: Left ventricular aneurysm (LVA) causes geometric changes, including reduced systolic function and a more spherical shape, which is quantified by the sphericity index (SI), the ratio of the short to long axis in the apical four-chamber view. This study aimed to assess SI's value in A-LVA and B-LVA, identify influencing factors, and evaluate its clinical relevance. : This clinical study included 54 patients with post-infarction LVA and used echocardiography to determine LVA locations (A-LVA near the apex and B-LVA in the basal segments), with SI and other echocardiographic measures assessed in both systole and diastole for the entire cohort and stratified by A-LVA and B-LVA groups.

View Article and Find Full Text PDF

This study sought to explore the clinical factors associated with classical low-flow low-gradient (C-LFLG) and normal-flow low-gradient (NFLG) aortic stenosis (AS) compared to high-gradient (HG) AS. We also compared clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR) across flow-gradient patterns. Patients with C-LFLG AS have a higher mortality rate after TAVR than those with HG AS.

View Article and Find Full Text PDF

Association with Outcome of the Regurgitant-Volume Adjusted Right Ventricular Ejection Fraction in Secondary Tricuspid Regurgitation.

J Am Soc Echocardiogr

January 2025

Department of Medicine and Surgery, University of Milano-Bicocca, Milan, Italy; Department of Cardiology, Istituto Auxologico Italiano, IRCCS, Milan, Italy.

Background: In patients with secondary tricuspid regurgitation (STR), right ventricular ejection fraction (RVEF) may not accurately reflect the actual RV systolic performance since a considerable amount of the RV stroke volume (SV) is regurgitated back into the right atrium. To overcome this limitation, we explored the association with the outcome of the effective RVEF (eRVEF), which accounts for the tricuspid regurgitant volume (RegVol).

Methods: 513 patients with STR (mean age 75±13 years, 39% atrial STR, 58% severe) underwent complete two-, three-dimensional, and Doppler echocardiography.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!