Article Abstract

Objectives: To validate an experimental setup designed to apply load onto bone tissue using osseointegrated implants in a rabbit model. Specifically, (1) to design an apparatus capable of generating controlled forces, (2) to assess implant placement, maintenance and loading and (3) to evaluate outcome variables using three radiological methods.

Material And Methods: New Zealand White rabbits were used. Two dental implants were inserted 15-18 mm apart in the animals' tibiae. After 3 months of healing, the implants were loaded normal to their long axes using a pneumatically activated device. A 15 min load regimen at 1 Hz was applied 5 days per week. Every week the applied load was increased by 5 N up to week 8 and by 10 N up to 100 N by week 14. Groups of animals (n=3) were sacrificed at load levels 25, 50 and 100 N. One unloaded controlateral implant in each group provided the baseline data. The rabbits were computer tomography (CT) scanned and radiographed using conventional frames every 4-5 weeks. After sacrifice, a volume of interest (VOI) located in the inter-implant zones and a VOI set as a ring surrounding the distal implant were analyzed using micro computer tomography (microCT).

Results: A variety of osseous responses was observed, ranging from minor alterations to significant increases in porosity and lamelling of the cortical layer. microCT data of the inter-implant VOI demonstrated an initial increase in total volume (upto 50 N) followed by stabilization. Concomitantly, bone volumetric density first decreased and then augmented until the end of the experiment. This phenomenon was not observed in the peri-implant VOI, for which volumetric density augmented from the beginning to the end of the experiment.

Conclusions: 1. In future trials the loading devices must be constructed so as to sustain heavy cyclic loads over prolonged periods. 2. When properly handled, rabbits are cooperative animals in this application. In a third of the sites, signs of inflammation were observed. 3. In the inter-implant VOI, the cortical bone tended to react in two phases: first, as an increase in porosity and lamelling and second, as an augmentation of bone volumetric density. The peri-implant VOI adapted only by augmenting volumetric density.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1600-0501.2008.01548.xDOI Listing

Publication Analysis

Top Keywords

volumetric density
16
computer tomography
8
porosity lamelling
8
inter-implant voi
8
bone volumetric
8
peri-implant voi
8
voi
6
bone
5
bone reactions
4
reactions controlled
4

Similar Publications

Strategies and Prospects for Engineering a Stable Zn Metal Battery: Cathode, Anode, and Electrolyte Perspectives.

Acc Chem Res

January 2025

Department of Chemistry, Shanghai Key Laboratory of Catalysis and Innovative Materials, Center of Chemistry for Energy Materials Shanghai, Fudan University, Shanghai 200433, PR China.

ConspectusZinc metal batteries (ZMBs) appear to be promising candidates to replace lithium-ion batteries owing to their higher safety and lower cost. Moreover, natural reserves of Zn are abundant, being approximately 300 times greater than those of Li. However, there are some typical issues impeding the wide application of ZMBs.

View Article and Find Full Text PDF

Background: Magnetic resonance imaging (MRI) has not been routinely used for infants with brachial plexus birth injury (BPBI); instead, the decision to operate is based on the trajectory of clinical recovery by 6 months of age. The aim of this study was to develop an MRI protocol that can be performed without sedation or contrast in order to identify infants who would benefit from surgery at an earlier age than the age at which that decision could be made clinically.

Methods: This prospective multicenter NAPTIME (Non-Anesthetized Plexus Technique for Infant MRI Evaluation) study included infants aged 28 to 120 days with BPBI from 3 tertiary care centers.

View Article and Find Full Text PDF

High-quality light-field generation of real scenes based on view synthesis remains a significant challenge in three-dimensional (3D) light-field displays. Recent advances in neural radiance fields have greatly enhanced light-field generation. However, challenges persist in synthesizing high-quality cylindrical viewpoints within a short time.

View Article and Find Full Text PDF

All-solid-state batteries (ASSBs) are pursued due to their potential for better safety and high energy density. However, the energy density of the cathode for ASSBs does not seem to be satisfactory due to the low utilization of active materials (AMs) at high loading. With small amount of solid electrolyte (SE) powder in the cathode, poor electrochemical performance is often observed due to contact loss and non-homogeneous distribution of AMs and SEs, leading to high tortuosity and limitation of lithium and electron transport pathways.

View Article and Find Full Text PDF

Crop rotation effects on the population density of soybean soilborne pathogens under no-till cropping system.

Plant Dis

January 2025

USDA-ARS North Central Agricultural Research Laboratory, Brookings, South Dakota, United States;

Soilborne diseases are persistent problems in soybean production. Long-term crop rotation can contribute to soilborne disease management. However, the response of soilborne pathogens to crop rotation is inconsistent, and rotation efficacy is highly variable.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!