Automatic intra-operative generation of geometric left atrium/pulmonary vein models from rotational X-ray angiography.

Med Image Comput Comput Assist Interv

Philips Research Laboratories, X-Ray Imaging Systems, Weisshausstrasse 2, D-52066 Aachen, Germany.

Published: December 2008

Pre-procedural imaging with cardiac CT or MR has become popular for guiding complex electrophysiology procedures such as those used for atrial fibrillation ablation therapy. Electroanatomical mapping and ablation within the left atrium and pulmonary veins (LAPV) is facilitated using such data, however the pre-procedural anatomy can be quite different from that at the time of intervention. Recently, a method for intra-procedural LAPV imaging has been developed based on contrast-enhanced 3-D rotational X-ray angiography (3-D RA). These intraprocedural data now create a compelling need for rapid and automated extraction of the LAPV geometry for catheter guidance. We present a new approach to automatic intra-procedural generation of LAPV surfaces from 3-D RA volumes. Using model-based segmentation, our technique is robust to imaging noise and artifacts typical of 3-D RA imaging, strongly minimizes the user interaction time required for segmentation, and eliminates inter-subject variability. Our findings in 33 patients indicate that intra-procedural LAPV surface models accurately represent the anatomy at the time of intervention and are comparable to pre-procedural models derived from CTA or MRA.

Download full-text PDF

Source
http://dx.doi.org/10.1007/978-3-540-85990-1_8DOI Listing

Publication Analysis

Top Keywords

rotational x-ray
8
x-ray angiography
8
anatomy time
8
time intervention
8
intra-procedural lapv
8
lapv
5
automatic intra-operative
4
intra-operative generation
4
generation geometric
4
geometric left
4

Similar Publications

Background: Vestibular dysfunction causing imbalance affects c. 80% of acute hospitalized traumatic brain injury (TBI) cases. Poor balance recovery is linked to worse return-to-work rates and reduced longevity.

View Article and Find Full Text PDF

Purpose: Previous studies reported that anterior knee pain (AKP) occurs with an incidence of 32% after opening-wedge high tibial osteotomy (OWHTO). However, the biomechanical effects of this procedure on patellofemoral joints (PFJs) remain unclear. We aimed to quantify the changes in the kinematics and cartilage conditions of the PFJ during stair climbing before and after OWHTO.

View Article and Find Full Text PDF

Rationale: Retained rectal foreign bodies (RFBs) are unusual clinical presentations whose management is challenging for emergency physicians owing to variations in the object types, anorectal anatomy, sacral curvature, insertion times, and local contamination. Here, we present the diagnosis and treatment in 1 case of retained rectal foreign body.

Patient Concerns: A 62-year-old male presented to the emergency department with a cosmetic bottle inserted into the rectum while bathing.

View Article and Find Full Text PDF

Influence of Axial Rotation Between the Femoral Neck and Ankle Joint on Kinematics in Normal Knees: A Cross-Sectional Study.

J Am Acad Orthop Surg Glob Res Rev

January 2025

From the Department of Orthopedic Surgery, Faculty of Medicine, The University of Tokyo, Bunkyo, Tokyo (Dr. Kono, Dr. Taketomi, Dr. Kage, Dr. Inui, and Dr. Tanaka); the Department of Information Systems, Faculty of Engineering, Saitama Institute of Technology, Fukaya, Saitama (Dr. Yamazaki); the Department of Orthopedic Biomaterial Science, Osaka University Graduate School of Medicine, Suita, Osaka (Dr. Tamaki, and Dr. Tomita); the Department of Orthopedic Surgery, Saitama Medical University, Saitama Medical Center, Kawagoe, Saitama (Dr. Inui); and the Department of Health Science, Graduate School of Health Science, Morinomiya University of Medical Sciences, Suminoe, Osaka, Japan (Dr. Tomita).

Background: The effect of axial rotation between the femoral neck and ankle joint (total rotation [TR]) on normal knees is unknown. Therefore, this study aimed to investigate the TR effect on normal knee kinematics.

Methods: Volunteers were divided into groups large (L), intermediate (I), and small (S), using hierarchical cluster analysis based on TR in the standing position.

View Article and Find Full Text PDF

We here explore confinement-induced assembly of whey protein nanofibrils (PNFs) into microscale fibers using microfocused synchrotron X-ray scattering. Solvent evaporation aligns the PNFs into anisotropic fibers, and the process is followed in situ by scattering experiments within a droplet of PNF dispersion. We find an optimal temperature at which the order parameter of the protein fiber is maximized, suggesting that the degree of order results from a balance between the time scales of the forced alignment and the rotational diffusion of the fibrils.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!