Using a silver-coated polymeric substrate for the management of chronic ulcerations: the initial Mayo Clinic experience.

Adv Skin Wound Care

Department of Physical Medicine and Rehabilitation, Mayo Clinic, Rochester, MN, USA.

Published: November 2008

Background: This retrospective observational study was designed to review the use of a silver-coated polymeric substrate on various types of chronic wounds at the Mayo Clinic in Rochester, Minnesota.

Methods: The study was set in a community and referral multidisciplinary vascular wound clinic. The authors identified the first 112 patients treated with a silver dressing in the center. Of these, 15 were lost to follow-up or had incomplete data. Ninety-seven patients were included in the study. Thirty-seven of these 97 patients had multiple wounds; however, 1 wound per person was randomly chosen for analysis. The median age of these patients was 69 years. A wound was considered healed when the wound was completely epithelialized. Of the 97 wounds evaluated, the primary etiologies were as follows: 20 (20.6%) were neurotrophic, 24 (24.7%) were ischemic (arterial, arteriolar, or vasculitic), 20 (20.6%) were venous, 7 (7.2%) were traumatic, and 16 (16.5%) were multifactorial. The silver dressing was the primary wound care product on all wounds. Silverlon (Argentum LLC, Chicago, Illinois) was the silver dressing used for this study. The frequency of dressing changes and use of secondary dressings, to keep the wound moist, were based on the amount of drainage, debris, and slough on the wound. Data pertaining to patient demographics, risk factors, wound etiology, noninvasive arterial vascular studies, frequency of dressing changes, wound discomfort, wound size, and wound duration were collected by retrospective chart review.

Results: Thirty-five of the 97 wounds (36.1%) healed. The 62 nonhealed wounds (63.9%) decreased in size by a median of 55.2%. Among the 68 patients who had reported discomfort before the study, 77.9% reported no change in discomfort, 17.7% reported increased pain, and 4.4% reported decreased pain.

Conclusion: A silver-coated polymeric substrate (Silverlon) can be used as an effective primary wound care dressing in patients with active wounds.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.ASW.0000323579.87700.ecDOI Listing

Publication Analysis

Top Keywords

silver-coated polymeric
12
polymeric substrate
12
wound
12
silver dressing
12
mayo clinic
8
primary wound
8
wound care
8
frequency dressing
8
dressing changes
8
wounds
7

Similar Publications

A multifunctional electronic dressing with textile-like structure for wound pressure monitoring and treatment.

J Colloid Interface Sci

February 2025

Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education & Key Disciplines Laboratory of Novel Micro-Nano Devices and System Technology, College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China. Electronic address:

In the treatment of infected wounds in bedridden or lying chair patients with mobility problems, improper wound care can lead to wound deterioration, prolong disease pain, increase treatment and care costs, and bring heavier psychological, physical, and economic burdens to patients. In the process of wound recovery, patients with mobility problems mainly face the comprehensive problems of poor air permeability, wound pressure could not be monitored, wound infection and slow healing. Therefore, in the process of wound care for such patients, it is imperative to develop a gas permeable dressing that can monitor the patient's wound compression status in real time and promote wound healing.

View Article and Find Full Text PDF

One-Dimensional Flexible Capacitive Sensor with Large Strain and High Stability for Human Motion Monitoring.

ACS Appl Mater Interfaces

October 2024

School of Textile Science and Engineering, Shaoxing University, Shaoxing, Zhejiang 312000, China.

Flexible capacitive sensors have attracted the attention of researchers owing to their simple structure, ease of realization, and wearability. Currently, flexible capacitive sensors mainly have three-dimensional and two-dimensional structures, which are subject to several limitations in their applications. A low-cost, high-efficiency, and continuously processable process was used to wrap nylon DTY (PA) filaments on the surface of silver-coated nylon (SCN) core yarns and impregnate them with waterborne polyurethane (WPU) to obtain SCN/PA/WPU composite yarns, which were then utilized in the design of SCN/PA/WPU for the preparation of one-dimensionally structured flexible capacitive sensors.

View Article and Find Full Text PDF

Objectives: To investigate the chemical and mechanical properties of polyphenylene sulfone (PPSU) depending on its composition and manufacturing.

Methods: Unfilled-PPSU1 and with antimicrobial silver coated zeolites filled-PPSU2 specimens were made of granulate-GR, filament-FI, or printed-3D. Scanning microscopy and X-ray spectroscopy were performed.

View Article and Find Full Text PDF

Transferrin (TRF), recognized as a glycoprotein clinical biomarker and therapeutic target, has its concentration applicable for disease diagnosis and treatment monitoring. Consequently, this study developed boronic acid affinity magnetic surface molecularly imprinted polymers (B-MMIPs) with pH-responsitivity as the "capture probe" for TRF, which have high affinity similar to antibodies, with a dissociation constant of (3.82 ± 0.

View Article and Find Full Text PDF

Surface Modification of Copper-Based Flakes for Conductive Polymer Composites.

Polymers (Basel)

June 2024

Faculty of Mechanical Engineering, University of Ljubljana, Aškerčeva Ulica 6, 1000 Ljubljana, Slovenia.

The physical properties as well as thermal and electrical stability of copper particles can be improved by surface protection, which mainly depends on the coating material. Our study was, therefore, focused on the rheological, thermal, mechanical and electrical characterization of polymer composites by comparing uncoated (Cu), silver-coated (Cu@Ag) and silica-coated (Cu@Si) copper flakes in low-density polyethylene at various volume concentrations (up to 40%). Interactions among particles were investigated by rheological properties, as these indicate network formation (geometrical entanglement), which is important for mechanical reinforcement as well as establishing an electric pathway (electrical percolation).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!