This study assessed reliability of split times obtained by handheld stopwatches (HHSs) compared with electronic timing (ET) during a 200-m sprint. Two HHS timing methods were compared with ET: single-split timers (SST) and multiple-split timers (MST). Twenty-six timers without previous experience were given instruction and completed practice trials until good agreement was achieved between ET and HHS. Trained runners (8 males, 10 females) were timed for each 25-m interval on a standard 200-m course. Repeated-measures analysis of variance and intraclass correlation models were used to determine reliability. A total of 248 split times were analyzed. No significant differences were found between the three timing methods (p > 0.99), and calculated intraclass correlation values were high (0.988). Mean error between SST, MST, and ET (-0.04 +/- 0.24 and -0.05 +/- 0.24 seconds, respectively) indicated faster HHS times, though not significantly. However, absolute errors were considerably larger (0.15 +/- 0.20 and 0.16 +/- 0.19 between SST, MST, and ET, respectively). The HHS-recorded splits were faster than ET in 67.3% of splits and slower in 29.4%. The distribution of errors made the development of a reliable correction factor to convert HHS to ET impossible. It was concluded that on the basis of the small mean error and high intraclass correlations, the use of HHSs may be a viable alternative to ET in collecting group data. However, on the basis of the absolute error between HHS and ET, when high degrees of precision are required, ET should be used, and reliable correction of HHS to ET values is not possible. It was further concluded that HHS times should be reported without attempting correction and interpreted in light of the shortcomings of the HHS method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1519/JSC.0b013e318185f36c | DOI Listing |
Resuscitation
October 2022
Section of Neonatology, Department of Pediatrics, Louisiana State University Health Sciences Center, Shreveport, LA, United States.
Background And Objectives: Heart rate (HR) assessment is important during neonatal resuscitation. The most reliable ways of assessing HR at birth are pulse oximetry (PO) and/or electrocardiograph (ECG). However, delayed recording time due to poor perfusion or probe and electrode placement has been a concern.
View Article and Find Full Text PDFInt J Sports Phys Ther
June 2022
Penn Therapy and Fitness, Good Shepherd Penn Partners.
Background: Currently available hand-held dynamometers (HHD) offer a more objective and reliable assessment of muscle force production as compared to a manual muscle test (MMT). Yet, their clinical utility is limited due to high cost. The ActivForce (AF) digital dynamometer is a new low-cost HHD with unknown psychometric properties, and its utilization may benefit clinical practice.
View Article and Find Full Text PDFBMC Vet Res
May 2022
Department of Farm Animals, Vetsuisse Faculty, University of Zurich, Winterthurerstrasse 260, CH-8057, Zurich, Switzerland.
J Family Med Prim Care
February 2021
III Year Post Graduate, Department of Physiology, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India.
Introduction: Assessment of skeletal muscle function (SMF) is of clinical relevance in the prediction of treatment outcome and to decide on optimal management of head & neck cancer (HNC) patients. Handgrip strength (HGS) & handgrip endurance (HGE) are considered as surrogate marker for whole-body skeletal muscle function. Further, SMF depends substantially on the body composition (BC).
View Article and Find Full Text PDFExp Gerontol
December 2020
Department of Epidemiology and Biostatistics, Schulich School of Medicine & Dentistry, University of Western Ontario, London, ON, Canada. Electronic address:
Background/objectives: Slow gait speed prospectively predicts elevated risk of adverse events such as falls, morbidity, and mortality. Additionally, gait speed under a cognitively demanding challenge (dual-task gait) predicts further cognitive decline and dementia incidence. This evidence has been mostly collected using electronic walkways; however, not all clinical set ups have an electronic walkway and comparability with simple manual dual-gait speed testing, like a stopwatch, has not yet been examined.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!