Purpose: To apply cross-correlation delay (XCD) analysis to myocardial phase contrast magnetic resonance (PCMR) tissue velocity data and to compare XCD to three established "time-to-peak" dyssynchrony parameters.

Materials And Methods: Myocardial tissue velocity was acquired using PCMR in 10 healthy volunteers (negative controls) and 10 heart failure patients who met criteria for cardiac resynchronization therapy (positive controls). All dyssynchrony parameters were computed from PCMR velocity curves. Sensitivity, specificity, and receiver operator curve (ROC) analysis for separating positive and negative controls were computed for each dyssynchrony parameter.

Results: XCD had higher sensitivity (90%) and specificity (100%) for discriminating between normal and patient groups than any of the time-to-peak dyssynchrony parameters. ROC analysis showed that XCD was the best parameter for separating the positive and negative control groups.

Conclusion: XCD is superior to time-to-peak dyssynchrony parameters for discriminating between subjects with and without dyssynchrony and may aid in the selection of patients for cardiac resynchronization therapy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5695683PMC
http://dx.doi.org/10.1002/jmri.21566DOI Listing

Publication Analysis

Top Keywords

dyssynchrony parameters
12
cross-correlation delay
8
phase contrast
8
contrast magnetic
8
magnetic resonance
8
resonance pcmr
8
pcmr velocity
8
velocity data
8
tissue velocity
8
negative controls
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!