Plastified poly(ethylene terephthalate) (PET)-toner microfluidic chip by direct-printing integrated with electrochemical detection for pharmaceutical analysis.

Talanta

Key Laboratory of Analytical Chemistry for Life Science, Department of Chemistry, Nanjing University, Nanjing 210093, China.

Published: February 2006

Rapid separation and determination of acetaminophen and its hydrolysate with end-channel electrochemical (EC) detection integrated on a plastified poly(ethylene terephthalate) (PET)-toner microchip capillary electrophoresis (CE) system was investigated. In this separation and detection system, a Pt ultramicroelectrode integrated on a three-dimensional adjustor was used as working electrode. Factors influencing the separation and detection were investigated and optimized. Results show that acetaminophen and p-aminophenol can be well separated within 84s with R.S.D.<1% for migration time and R.S.D.<3.6% for detection current for both analytes. Detection limits for both analytes are determined to be 5.0muM (S/N=3). This method has been successfully applied to the detection of trace p-aminophenol in paracetamol tablets. The results demonstrate that the PET-toner microchips can obtain better performance than PDMS microfluidic devices but at much lower cost.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2005.07.043DOI Listing

Publication Analysis

Top Keywords

plastified polyethylene
8
polyethylene terephthalate
8
terephthalate pet-toner
8
electrochemical detection
8
separation detection
8
pet-toner microfluidic
4
microfluidic chip
4
chip direct-printing
4
direct-printing integrated
4
integrated electrochemical
4

Similar Publications

Rapid separation and determination of acetaminophen and its hydrolysate with end-channel electrochemical (EC) detection integrated on a plastified poly(ethylene terephthalate) (PET)-toner microchip capillary electrophoresis (CE) system was investigated. In this separation and detection system, a Pt ultramicroelectrode integrated on a three-dimensional adjustor was used as working electrode. Factors influencing the separation and detection were investigated and optimized.

View Article and Find Full Text PDF

Electrokinetic control of fluid in plastified laser-printed poly(ethylene terephthalate)-toner microchips.

Anal Bioanal Chem

May 2005

Key Laboratory of Analytical Chemistry for Life Science, Department of Chemistry, Nanjing University, Nanjing, 210093, PR China.

The application of plastified laser-printed poly(ethylene terephthalate)(PET)-toner microchips to capillary electrophoresis was investigated. Electroosmotic flow was observed in the direction of the cathode for the buffer system studied (phosphate, pH 3-10). Average electroosmotic mobilities of 1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!