A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

On-line determination of trace sulfur dioxide in air by integrated microchip coupled with fluorescence detection. | LitMetric

On-line determination of trace sulfur dioxide in air by integrated microchip coupled with fluorescence detection.

Talanta

Department of Chemistry, Graduate School of Science, Tokyo Metropolitan University, 1-1 Minami-Ohsawa, Hachioji, 192-0397 Tokyo, Japan.

Published: September 2005

A microchip-based method was developed for on-line determination of trace sulfur dioxide (SO(2)) in air. Gaseous SO(2), which diffused through the porous glass materials on the microchip, was absorbed into an absorption solution of triethanolamine (TEA) as sulfite ions and reacted with N-(9-acridinyl)maleimide (NAM), which was used as a fluorescent reagent. The fluorescence of NAM-sulfite in micro-fluidic channel was detected. The calibration curve of sulfite ions in the range of 1.5-30mumol/L (SO(2) 3-60ppbv) showed a linear relation R(2)=0.995, and the relative standard deviation (R.S.D.) was 1.9% for 10mumol/L sulfite ions in five measurements. The entire measurement procedure was achieved by the integrated microchip, and the consumption of reagents was drastically reduced. It was satisfactory to apply this method to determine on-line the SO(2) level in the air.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2005.03.017DOI Listing

Publication Analysis

Top Keywords

sulfite ions
12
on-line determination
8
determination trace
8
trace sulfur
8
sulfur dioxide
8
integrated microchip
8
dioxide air
4
air integrated
4
microchip coupled
4
coupled fluorescence
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!